STP Classic Control:

Make sure that steam generator is OFF. Remove the cap of tee pipe in the 

over pressure valve piping. Pour the decalcifying solution into the tank. 

Return back the cap to its original position when done.

Turn ON the steam generator and wait until water inside the tank starts to 

boil. Let the solution boil for 5 minutes.

If standby mode is available:

Press shortly Standby button. Steam generator goes to standby mode 

and  after  time  expires,  water  will  be  drained  automatically.  After 

draining screen goes to OFF state. If autodrain is not available then 

drain by pulling lever down.

If standby mode is not available:

Turn  OFF  the  steam  generator.  Let  the  solution  stay  in  the  tank  30 

minutes and then drain manually by pulling lever down.

Fill and drain the tank with water two times more by switching ON and 

draining the steam generator.

SST/STP Touch Control:

Turn ON the steam generator.

Go to Settings menu by pressing three seconds the settings icon. Scroll 

to the “Decalcifying” menu and press “Start”. Confirm by pressing “OK”.

Next process shows that water is filled in the tank. After water is filled, 

add decalcifying solution: Remove the cap of tee pipe in the over pressure 

valve piping. Pour the decalcifying solution into the tank. Return back the 

cap to its original position when done.

After pouring the solution, press “OK” on the screen. Steam generator will 

automatically  go  through  decalcifying  process  including  draining.  After 

process is done, screen will go to off state. Fill and drain the tank with 

water two times more by switching ON and draining the steam generator.

Use Decalcifying Solution as follows:

1.

2.

3.1

3.2

4.

1.

2.

3.

4.

Steam 

Generator 

(kW)
3-7,5

9-15

Decalcifying 

Solution 

(ml)

250
500

Maintenance

Decalcification

Tap water contains impurities, for example lime, that can cause calcium deposit and block the internal parts of the steam 
generator. To prevent this and prolong the lifetime of steam generator it is recommended to have a water filter and water 
softener. They are connected to the water source of the steam generator’s water inlet.

SAWO Decalcifying Solution can be used for decalcification. Follow these guidelines to perform preventative maintenance of 
the steam generator.

For  steam  generators  in  commercial  use  (over  5  hours 
continuously  daily)  additional  service  plan  is  recommended 
twice a year. Please contact your service center for details.

Frequency for decalcification:

Unit dH where 1 dH is 10 mg calcium in 1 liter of water

< 3 ºdH = very soft water, decalcification every 500 operation hours
3-6 ºdH = soft water, decalcification every 100 operation hours
6-9 ºdH = hard water, decalcification every 50 operation hours
9-18 ºdH = very hard water, decalcification every 30 operation hours

WARNING!

Never  add  the  Decalcifying 

Solution when the generator is 

on, it can cause serious burns!

Decalcifying Solution

Cap

Summary of Contents for STN Series

Page 1: ...DISTRIBUTOR S MANUAL 2 Heating Elements 3 Heating Elements 6 Heating Elements 3 0 kW 3 5 kW 4 0 kW 4 5 kW 5 0 kW 4 5 kW 6 0 kW 7 5 kW 9 0 kW 12 0 kW 15 0 kW STN Steam Generators...

Page 2: ...of Use Technical Data PCB Parts DIP Switches Steam Generator Dimensions Choosing Correct Kilowatt Size Steam Generator Piping Steam Head Location OFF ON Mode Standby Mode Auto drain Mode Switching Be...

Page 3: ...be strategic for servicing and maintenance Do not place the steam generator inside the steamroom or outdoors Make sure that water or liquids cannot come in touch with the generator Generator is not sp...

Page 4: ...Automatic Drain Thread 1 BSP Thread 1 BSP 2 Heating Elements 3 Heating Elements 6 Heating Elements Steam Head 9kW 12kW and 15kW include two steam heads Steam Head Holder Optional Items Steam Generator...

Page 5: ...vy Walls Natural stones marble stone concrete wall Porcelain tiles on top of concrete wall Based on light walls Example 1 Steam room has tiled walls Tiles are not on top of thick concrete Example 3 St...

Page 6: ...age the unit due to climate conditions 4 Do not install the steam generator or plumbing lines in unheated attic or any locations where water could freeze 5 The steam generator must not be installed in...

Page 7: ...g the steam line down and then up will create a steam trap blocking the flow of the steam No trapping Union Do not use 1 steam line when installing 2 steam generators kW 3 7 5 9 and above Steam Line 1...

Page 8: ...em can be found in the text and graph following On Off Mode When the power switch is turned On the software versions of the control board and the user interface will be displayed for 1 second each The...

Page 9: ...letes Auto drain Mode The auto drain feature automatically drains the water system after every use The tank is flushed and will remain empty until the steam generator is used again After the Standby t...

Page 10: ...be displayed Key Lock Lock and unlock the key pad by pressing the up and down buttons at the same time for more than 5 seconds A high beep will confirm the activation and the deactivation Only On Off...

Page 11: ...anged by pressing up or down arrow buttons between 1 scent pump is activated every 20 mins and 20 pump on continuously If no keys are pressed within 5 seconds the previously displayed value will be sh...

Page 12: ...485 STN 75 3 7 5 4 15 2 5 2 5 1N 2N STG 150 STG 200 19 560 185 485 220 240 380 415 19 9 STN 35 1 2 3 5 3 5 max 1 x 1 5 kW 1 x 2 0 kW 2 x 2 0 kW 1 x 2 0 kW 1 x 2 5 kW 3 x 1 5 kW STG 150 4 5 2 5 3 x 1...

Page 13: ...20mA 230 VAC Max 100W 230 VAC Max 100W 230 VAC Max 100W FUSE F1 1 6A F2 1 6A 230VAC 1N SERIAL NUMBER 24 VAC IN CONTACTOR DRAIN FILL TERMINAL CONNECTORS Demand button illumination GND 12VDC 25mA Demand...

Page 14: ...nt Connected Yes 30 50 C Not Present Not Present Not Connected No Fan Scent Pump Auto Drain Temperature range Slave Unit Slave Number Slave Number DIMMER FAN SCENT PUMP DRAIN TEMP SLAVE STANDBY SESSIO...

Page 15: ...ed Disabled Disabled Max temperature is 50Deg Cel Enabled Automatically drains Turn off after 30mins 1 1100 000 0 0 0 0 0 1 Steam Generator Control Master Steam Generator DIP SW 3 OFF DIP SW 3 ON 2 OF...

Page 16: ...DIP switches This helps troubleshooting in case of malfunction If an error occurs in one of the slave units error message is followed by a slave number For example E1 S2 E1 S2 Pressing ON OFF button...

Page 17: ...HEATING ELEMENTS CONTACTOR UNIT CONTROL BOARD FUSE NTC2 TEMP SWITCH ill Fan Max 100W Light Scent Pump Auto Drain See page 21 12V DC Switch Temperature Sensor 7 5 meters STP Classic STP Classic 2 0 STP...

Page 18: ...3 L2 L1 N G L3 L2 L1 CONTROL BOARD FUSE NTC2 TEMP SWITCH ill Fan Max 100W Light Scent Pump Auto Drain See page 21 12V DC Switch Temperature Sensor 7 5 meters STP Classic STP Classic 2 0 STP SST 380 41...

Page 19: ...nd Interface PCB It is also being displayed at the Start up Sticker locations for software versions Software versions displayed at Start up Software Compatibility TOUCH USER INTERFACE BOARD STP BOARD...

Page 20: ...floor away from the steam head so that the steam will not hit the sensor directly 2 A 25mm hole is required to insert the temperature sensor Do not create bigger or smaller hole Clean the hole before...

Page 21: ...mer Steam room light can be connected to steam generator s light output Output is 230VAC fused Demand Button IP 68 sealed when panel mounted Can be installed inside or outside steam room Button has bl...

Page 22: ...N SCENT PUMP TEMP SWITCH 24VAC DRAIN 230VAC LIGHT 12VDC ILL Scent Pump Dosing nozzle should be installed above steam head in order to maximize aroma flow to steam room Back flow of Aroma to steam gene...

Page 23: ...tion when done After pouring the solution press OK on the screen Steam generator will automatically go through decalcifying process including draining After process is done screen will go to off state...

Page 24: ...ottom plug and use teflon pipe seal if needed 7 Attach heating elements Make sure that temperature fuse and tank tempesensor are on the top of heating element Inserting heating element upside down wil...

Page 25: ...probes If no problem can be found contact the retailer Clean level probes If no problem can be found contact the retailer Check that water supply is open and there is enough pressure Check solenoid v...

Page 26: ...att 16 Cover Plate 17 Steam Head Holder 18 Steam Head 19 Room Temperature Sensor 20 RJ12 Extension Cable 15m 2m 21 STP STN Control Unit 22 Thermal Fuse 23 Tank Temperature Sensor Spare Parts 1 2 4 3 7...

Reviews: