TECHNICAL GUIDE
STN Steam Generators
www.sawo.com | [email protected]
15
DIMMER
FAN
SCEN
T PUMP
DRAIN
TEMP
SL
AVE
OFF
S
TANDBY
SESSION
1
=
=
ON
OFF
0
STAND-BY IN USE
DIMMER
FAN
SCEN
T PUMP
DRAIN
TEMP
SL
AVE
OFF
S
TANDBY
SESSION
1
=
=
ON
OFF
0
SKIP STAND-BY
ON
DIP
DIP
ON
ON
DIP
DIP
ON
Example #1
Example #2
Stand-by
Maximum
Session Time
Maximum
Stand-by Time
Slave
Scent
Fan
Dimmer
Temp
Drain
Stand-by in Use
30 min.
4 hrs.
Steam generator is MASTER.
Scent
Fan
Dimmer
Max. temperature is 50Deg.Cel
Enabled: Tank will be drained
right after stand-by mode has
expired.
0
0011
000
0
1
1
1
0
1
Stand-by
Maximum
Session Time
Maximum
Stand-by Time
Slave
Scent
Fan
Dimmer
Temp
Drain
Skip Stand-by
Unlimited
No effect since Stand-by is
Disabled.
Steam generator is MASTER
Disabled
Disabled
Disabled
Max. temperature is 50Deg.Cel
Enabled: Automatically drains.
Turn-off after 30mins.
1
1100
000
0
0
0
0
0
1
Steam Generator
Control
Master
Steam Generator
DIP SW
3 = OFF
DIP SW
3 = ON
2 = OFF
1 = OFF
DIP SW
3 = ON
2 = OFF
1 = ON
DIP SW
3 = ON
2 = ON
1 = ON
DIP SW
3 = ON
2 = ON
1 = OFF
Slave 1
Steam Generator
Slave 2
Steam Generator
Master
Steam Generator
Slave 1
Steam Generator
Slave 3
Steam Generator
Slave 4
Steam Generator
RJ12 Cable
LAST UNIT IN CHAIN
HAS JUMPER PLACED
JUMPER REMOVED
JUMPER REMOVED
TO SLAVE 1
FROM CONTROL
JUMPER REMOVED
WITH JUMPER
TO SLAVE 2
FROM MASTER
Ending Data Line
Make sure that the highlighted
jumper is always in the last PCB
of the chain. If there is only one
board, leave the jumper on that
board. If more than one board is
used, take the jumpers out of all
the boards, except the last one in
the chain.
Slave
No.
Switch
1
Switch
2
1
0
0
2
0
1
3
1
0
4
1
1
Dipswitches for
Naming Slaves
Steam Generator Series Connection