TECHNICAL GUIDE
STN Steam Generators
www.sawo.com | [email protected]
21
Cabin lights /
Dimmer
230/12, 24, 230
FAN
SCENT PUMP
TEMP
SWITCH
(24VAC)DRAIN
(230VAC) LIGHT
(12VDC)ILL
FAN
SCENT PUMP
TEMP
SWITCH
(24VAC)DRAIN
(230VAC) LIGHT
(12VDC)ILL
Cabin Light
For safety reasons use step down transformer 24-12VAC and low voltage lighting fixture.
If 230VAC is used, it’s highly recommended to use isolation transformer.
Steam room light can be connected to steam generator’s light output. Output is 230VAC fused.
Demand Button
•
IP 68 sealed when panel mounted.
•
Can be installed inside or outside steam room.
•
Button has blue ring illumination. 5VDC and 20mA. Make sure polarity is right when connecting illumination wires.
•
4-pole connection cable. 2 poles for switch and 2 poles for illumination.
10 meters connection cable
Wire Color Connections
Terminal block (Steam Generator)
Terminal block
Demand Button
Connection
Cable
Red
Yellow
Grey
White
Brown
Green
Switch
Switch
-ILL
-ILL
-ILL
+ILL
Terminal Block
Terminal Block