10
www.sawo.com | [email protected]
TECHNICAL GUIDE
STN Steam Generators
Temperature / Timer
The temperature/timer button can be used to switch between the temperature and session time.
When the steam generator is switched on, the set temperature at the steam room is displayed. It can be changed by pressing
up and down buttons.
If the temperature/timer button is pressed, the remaining session time will be displayed. It can be changed by pressing up
and down buttons. The session time will be saved as the default session time if it was changed within the first 5 mins from the
beginning of “On” mode.
If the temperature/timer button is pressed again, the unit will return displaying the set temperature. In addition, if no buttons
are pressed for 10 seconds, the set temperature of the steam room will be displayed.
Key Lock
Lock and unlock the key pad by pressing the up and down buttons at the same time
for more than 5 seconds. A high beep will confirm the activation and the deactivation.
Only On/Off, Standby and Cabin light buttons are usable when the key pad is locked. If
other buttons are pressed, “----” is shown in the display.
The key lock function is set automatically if it was left active during the previous operation.
Changing the values
Pressing the up or down button in the settings menu will in- or decrease the currently
displayed value. A value cannot be in- or decreased above or below its maximum or
minimum value, if it is tried low tone buzzer alarms the user.
The up and down buttons are repetitive. Holding the up or down button will cause the
value to in- or decrease with an increased rate.
If no keys are pressed within 5 seconds, changes in the values are confirmed.
In the “On” mode, if no keys are pressed for 10 seconds, the display will automatically
display the set temperature.