37
2000225294A
11 Electrical Connections
WARNING:
This appliance must be earthed. This appliance
must be wired in accordance with these instructions. Any fault
arising from incorrect wiring cannot be put right under the terms
of the Saunier Duval guarantee.
All system components must be of an approved type.
Do not interrupt the mains supply with a time switch or
programmer.
Connection of the whole electrical system and any heating
system controls to the electrical supply must be through a
common isolator.
Isolation should preferably be by a double pole switched fused
spur box having a minimum contact separation of 3mm on each
pole. The fused spur box should be readily accessible and
preferably adjacent to the boiler. It should be identified as to its
use.
A fused three pin plug and shuttered socket outlet may be used
instead of a fused spur box provided that:
a) They are not used in a room containing a fixed bath or
shower.
b) Both the plug and socket comply with the current issue of
BS1363.
IMPORTANT:
If a replacement mains supply cable is required
it must be purchased. Part Number S1008600.
11.1 External Controls - Voltage Free
WARNING:
UNDER NO CIRCUMSTANCES MUST ANY
MAINS VOLTAGE BE APPLIED TO ANY OF THE TERMINALS
ON THE VOLTAGE FREE HEATING CONTROLS
CONNECTION.
Diagram 11.2
CONTROL
PANEL REAR
COVER
SECURING
SCREW (3)
VOLTAGE FREE
HEATING
CONTROLS
CONNECTION
WIRE
LINK (E)
Diagram 11.1
12224
11985
RETAINING
SLOTS
RETAINING
CORD
Lower the control panel.
This boiler will operate continuously on heating as supplied, if
the wire link (E), fitted between the two terminals of the heating
controls connection, is left in place,
see diagram 11.1.
System heating controls e.g. Room thermostat, should be fitted
in accordance with the rules in force.
Refer to
diagram 11.2
.
(F24e & F28e ONLY)
(F24e & F28e ONLY)
11.2 External Controls - Mains Voltage
WARNING:
UNDER NO CIRCUMSTANCES MUST ANY
MAINS VOLTAGE BE APPLIED TO ANY OF THE TERMINALS
ON THE VOLTAGE FREE HEATING CONTROLS
CONNECTION PLUG.
Remove the MAINS VOLTAGE HEATING CONTROLS
CONNECTION PLUG from the fittings pack and install on the
230V control board as the following text describes.
Gain access to the 230V controls board by unclipping the
control panel user interface and carefully lower forward, see
diagram 11.3.
Remove the wire link (E) from the voltage free heating controls
connection plug
diagram 11.3,
connect the external controls as
shown in
diagram 11.5,
connect the mains voltage heating
controls connection plug and external controls cable to the
230V controls board, then route the external controls cable as
shown in
diagram 11.4.
Gain access to the rear of the control panel,
see diagram 11.1.
Thread the external controls cable through the front, close the
control panel user interface and secure the cable in the strain
relief,
see diagram 11.4.
Summary of Contents for EnviroPlus F24e
Page 18: ...18 2000225294A Diagram 5 1 11907 5 Boiler Schematic F24e F28e ONLY ...
Page 19: ...19 2000225294A 5 Boiler Schematic Diagram 5 1a 12248 BYPASS F28e SB ONLY ...
Page 49: ...49 2000225294A 14 Fault Finding 12410 Diagram 14 4 ...
Page 51: ...51 2000225294A 15 Wiring Diagram Diagram 15 1a 12240 F28e SB ONLY ...