Section 3: Configuration
XL400/410e Operator’s Manual
Page 3-3
3.1 PRINTER DIP SWITCH CONFIGURATION (CONT’D)
Stop Bit Selection (DSW1-4): Selects the number of Stop bits to end each byte’s transmission.
Baud Rate Selection (DSW1-5, DSW1-6): Selects the data rate (bps) for the RS232 port.
Protocol Selection (DSW1-7, DSW1-8): Selects the flow control and status reporting protocols.
See Section
5
: Interface Specifications for more information..
Printer Set up
Print Mode Selection (DSW2-1): Selects between direct thermal printing on thermally sensitive
paper and thermal transfer printing using a ribbon.
Reserved (DSW2-2): Reserved for future use.
Head Check Selection (DSW2-3): When selected, this option causes the printer to check for
head elements that are electrically malfunctioning..
DSW1-4
Setting
Off
1 Stop Bit
On
2 Stop Bits
DSW1
ON
OFF
1
2
3
4
5
6
7
8
DSW1-5
DSW1-8
Setting
Off
Off
9600
Off
On
19200
On
Off
4800
On
On
2400
DSW1
ON
OFF
1
2
3
4
5
6
7
8
DSW1-5
DSW1-8
Setting
Off
Off
Ready/Busy
Off
On
X-On/X-Off
On
Off
Bi-Com
On
On
Not Used
DSW1
ON
OFF
1
2
3
4
5
6
7
8
DSW2-1
Setting
Off
Thermal Xfer
On
Direct Therm
DSW2
ON
OFF
1
2
3
4
5
6
7
8
DSW2-1
Setting
Off
Disabled
On
Enabled
DSW2
ON
OFF
1
2
3
4
5
6
7
8