SATO 8310-00 Instruction Manual Download Page 6

 

 

Loading and Replacing Battery 

 

Use a “+” screwdriver to loosen the screw on the battery compartment. 

  Remove the old battery if replacing the battery. 

  Set a new

 

9VDC Battery 6F22 (006P)

 

with correct polarity (+ and -) marked inside the 

battery compartment.

 

  Close the battery cover and secure it with the screw. 

Note

:  An alarm setting value or a measurement ambient setting is not reset even if a battery 

is removed.   

 

CAUTION 

 

Once the “Low Battery Mark” starts to flash, replace with a new battery immediately. 

 

Under 

the “Low Battery Mark” flashing, accurate measurement cannot be expected. 

 

Always use a new battery for replacement. 

 

How to Measure 

  Expose the sensing section by tuning the cover. 

  Turn on the power by pressing the POWER key.   

  Select  a  measurement  mode  by  pressing  the  MODE/Up  key.  The  display  changes  in 

following order. 

 

 

 

 

 

 

 

 

 

 

 

 

  Set  the  instrument  far  away  from  your  body  by  holding  the  lower  part  of  the  unit  for 

accurate measurement or use the instrument fixed onto a camera tripod. 

Note

: Measuring conditions such as measurement height differ by purpose of use. 

  Press the POWER key to end the measurement. 

Note

: Always close the sensing section

 

for storing. 

 

WBGT(WBGT) 

Temperature(TA) 

 

Humidity(RH) 

Globe Temperature(TG) 

Summary of Contents for 8310-00

Page 1: ...INSTRUCTION MANUAL No 8310 00 Heat Stress Monitor Model SK 150GT...

Page 2: ...this instrument before use for proper usage This instrument does not prevent a heat stress This instrument indicates WBGT index which can be used as guidelines for general heat stress Heat stress is...

Page 3: ...sed battery into a fire Keep battery out of reach of children If swallowed seek a medical attention immediately Dispose the used battery according to your local rules and regulations Please contact us...

Page 4: ...he values manually SET Press this key to set an alarm In WBGT mode press longer than 2 sec to enter the alarm setting mode Press the key longer than 2 sec in alarm setting mode to fix the set value an...

Page 5: ...itor measured data on a PC LCD Display 7 segment Display Display for Temperature TA Globe Temperature TG Relative Humidity RH or WBGT Index WBGT Also it displays the set value in alarm setting mode MI...

Page 6: ...the Low Battery Mark flashing accurate measurement cannot be expected Always use a new battery for replacement How to Measure Expose the sensing section by tuning the cover Turn on the power by pressi...

Page 7: ...ment fully adapt to measuring ambient without condensing before use Handle the globe with great care Damages on the globe or its finishing can have an effect on the measurement accuracy HOLD Function...

Page 8: ...20 0 to 49 9 C It is not possible to disable the alarm function If you do not want the alarm to be alerted set the alarm to its maximum limit 49 9 C Press the SET key for longer than 2 seconds to con...

Page 9: ...n jack on the right side of the unit Connect the 9 pin connector of the cable to the serial port of your computer Turn the power on to active the measurement mode The measurement data will be transmit...

Page 10: ...could be malfunctioning Stop using the instrument and contact the dealer of your purchase or our company for further assistance E33 The internal electrical circuit is malfunctioning Stop using the ins...

Page 11: ...Temperature Thermistor Humidity Electrostatic capacitance type sensor Alarm for WBGT Setting Range 20 0 to 49 9 C in 0 1 C step no deactivation Operation Ambient 0 to 50 C less than 95 rh no condensi...

Page 12: ...3 4 Kanda kajicho Chiyoda ku Tokyo 101 0045 Japan URL http www sksato co jp english...

Reviews: