If the instrument gets condensed with moisture, turn the power off immediately and let it 

dry naturally before using it again. 

 

If the instrument is used in a noisy environment, the instrument could show unstable 

values and errors in accuracy. 

 

Never disassemble or alter the instrument to avoid any malfunctions and damages. 

 

This is a precision instrument. Be careful not to drop or give shocks to it. 

 

Do not wash or wipe this unit with alcohol, thinner, or any other solvents. If the unit gets 

dirty, wipe it with a tightly wrung towel that has been dipped in warm detergent water. 

 

If the instrument is not in use for a long period of time, always remove the battery. 

Otherwise, the battery power may be wasted and the battery fluid may leak, resulting 

malfunctions.   

 

Do not dispose the used battery into a fire. 

 

Keep battery out of reach of children. If swallowed, seek a medical attention 

immediately. 

 

Dispose the used battery according to your local rules and regulations. 

Please contact us or a distributor for repairs or calibrations. 

 

Overview 

The SK-150GT is a handy type heat stress monitor which can measure globe temperature, 

air temperature and relative humidity at the same time. From the measured values, this 

instrument can calculate the WBGT index which is used as a preventive measure for a heat 

stress and a guideline for proper working environment.   

 

Features 

 

The instrument can measure globe temperature, air temperature and relative humidity at 

the same time, good for general environment monitoring 

 

Auto Power-Off after 20 minutes for power-saving purpose. 

 

HOLD function 

 

MAX/MIN function   

 

Alarm function for WBGT 

 

Portable (handy) type 

 

Fixable to a standard camera tripod 

 

Optional RS232C Cable available to send measured data to a PC for real-time 

monitoring 

Summary of Contents for 8310-00

Page 1: ...INSTRUCTION MANUAL No 8310 00 Heat Stress Monitor Model SK 150GT...

Page 2: ...this instrument before use for proper usage This instrument does not prevent a heat stress This instrument indicates WBGT index which can be used as guidelines for general heat stress Heat stress is...

Page 3: ...sed battery into a fire Keep battery out of reach of children If swallowed seek a medical attention immediately Dispose the used battery according to your local rules and regulations Please contact us...

Page 4: ...he values manually SET Press this key to set an alarm In WBGT mode press longer than 2 sec to enter the alarm setting mode Press the key longer than 2 sec in alarm setting mode to fix the set value an...

Page 5: ...itor measured data on a PC LCD Display 7 segment Display Display for Temperature TA Globe Temperature TG Relative Humidity RH or WBGT Index WBGT Also it displays the set value in alarm setting mode MI...

Page 6: ...the Low Battery Mark flashing accurate measurement cannot be expected Always use a new battery for replacement How to Measure Expose the sensing section by tuning the cover Turn on the power by pressi...

Page 7: ...ment fully adapt to measuring ambient without condensing before use Handle the globe with great care Damages on the globe or its finishing can have an effect on the measurement accuracy HOLD Function...

Page 8: ...20 0 to 49 9 C It is not possible to disable the alarm function If you do not want the alarm to be alerted set the alarm to its maximum limit 49 9 C Press the SET key for longer than 2 seconds to con...

Page 9: ...n jack on the right side of the unit Connect the 9 pin connector of the cable to the serial port of your computer Turn the power on to active the measurement mode The measurement data will be transmit...

Page 10: ...could be malfunctioning Stop using the instrument and contact the dealer of your purchase or our company for further assistance E33 The internal electrical circuit is malfunctioning Stop using the ins...

Page 11: ...Temperature Thermistor Humidity Electrostatic capacitance type sensor Alarm for WBGT Setting Range 20 0 to 49 9 C in 0 1 C step no deactivation Operation Ambient 0 to 50 C less than 95 rh no condensi...

Page 12: ...3 4 Kanda kajicho Chiyoda ku Tokyo 101 0045 Japan URL http www sksato co jp english...

Reviews: