SATO 8310-00 Instruction Manual Download Page 4

 

 

Names of Components

 

Main Unit

 

 

 

 

 

Display Section 

Measured values and state of the main unit are displayed. 

* Refer to 

“LCD Display” for details 

 

 

POWER 

On/Off key 

Press this key to turn the main unit on. Press it again to turn off. 

 

 

HOLD 

This key holds a measured value.   

Press this key to HOLD data. Press the key again to release HOLD. 

 

 

MN/MX/RST   

A changeover switch for max. and min. values.   

Press this key to display the min. or max. value in the measurement 

mode. Press it longer than 2 sec. to reset the values manually. 

 

 

SET 

Press this key to set an alarm.   

In WBGT mode, press longer than 2 sec. to enter the alarm setting 

mode. Press the key longer than 2 sec. in alarm setting mode to fix 

the set value and return to measurement mode. 

 

 

IN/OUT/NEXT   

A changeover switch for the setting of indoor and outdoor WBGT.   

Press this key longer than 2 sec. in WBGT mode to changeover to 

set either indoor (IN) or outdoor (OUT)     

In alarm setting mode, press it to change digits 

 

 

MODE/UP 

A changeover switch for displaying measured values. 

In measuring mode, press this key 

to switch to “Temperature (TA)”, 

“Globe Temperature (TG)”, “Relative Humidity (RH)” or “WBGT 
(WBGT)”.   

Press at alarm setting mode to increase the setting value. 

Summary of Contents for 8310-00

Page 1: ...INSTRUCTION MANUAL No 8310 00 Heat Stress Monitor Model SK 150GT...

Page 2: ...this instrument before use for proper usage This instrument does not prevent a heat stress This instrument indicates WBGT index which can be used as guidelines for general heat stress Heat stress is...

Page 3: ...sed battery into a fire Keep battery out of reach of children If swallowed seek a medical attention immediately Dispose the used battery according to your local rules and regulations Please contact us...

Page 4: ...he values manually SET Press this key to set an alarm In WBGT mode press longer than 2 sec to enter the alarm setting mode Press the key longer than 2 sec in alarm setting mode to fix the set value an...

Page 5: ...itor measured data on a PC LCD Display 7 segment Display Display for Temperature TA Globe Temperature TG Relative Humidity RH or WBGT Index WBGT Also it displays the set value in alarm setting mode MI...

Page 6: ...the Low Battery Mark flashing accurate measurement cannot be expected Always use a new battery for replacement How to Measure Expose the sensing section by tuning the cover Turn on the power by pressi...

Page 7: ...ment fully adapt to measuring ambient without condensing before use Handle the globe with great care Damages on the globe or its finishing can have an effect on the measurement accuracy HOLD Function...

Page 8: ...20 0 to 49 9 C It is not possible to disable the alarm function If you do not want the alarm to be alerted set the alarm to its maximum limit 49 9 C Press the SET key for longer than 2 seconds to con...

Page 9: ...n jack on the right side of the unit Connect the 9 pin connector of the cable to the serial port of your computer Turn the power on to active the measurement mode The measurement data will be transmit...

Page 10: ...could be malfunctioning Stop using the instrument and contact the dealer of your purchase or our company for further assistance E33 The internal electrical circuit is malfunctioning Stop using the ins...

Page 11: ...Temperature Thermistor Humidity Electrostatic capacitance type sensor Alarm for WBGT Setting Range 20 0 to 49 9 C in 0 1 C step no deactivation Operation Ambient 0 to 50 C less than 95 rh no condensi...

Page 12: ...3 4 Kanda kajicho Chiyoda ku Tokyo 101 0045 Japan URL http www sksato co jp english...