2
. Alarm signals:
Wind speed : Alarm 1
①
Non-voltage contact (Make signal)
②
Green LED blinking (slow blinking)
③
Buzzer sound (slow intermittent sound)
Alarm 2
①
Non-voltage contact (Make signal)
②
Yellow LED blinking (fast blinking)
③
Buzzer sound (fast intermittent sound)
Alarm 3
①
Non-voltage contact (Make signal)
②
Red LED light (continuous light)
③
Buzzer sound (continuous sound)
Wind direction:
①
Non-voltage contact (Make signal)
* Alarm contact signal is output from Alarm 3
②
16 Azimuth LED: LEDs of Alarm section are blinking
. Output contact capacity
: 24VDC, 1A (resistance load)
6. External Outputs (Option)
Analog output
. Output
: 2 channels
. Output elements : available to set the output elements for each channel
CH1: Instantaneous wind speed : 0 to 90m/s / 0 to 1V
Mean wind speed : 0 to 90m/s / 0 to 1V
CH2: Instantaneous wind direction : 0 to 540° / 0 to 1V
Mean wind direction : 0 to 540° / 0 to 1V
* Available to set the output span by every 10m/s
* Output impedance: less than 500ohm
Digital output
. Signal system
: RS-422
. Output
: 1 channel
. Requirements
: Transmission speed
300, 1200, 2400, 4800, 9600, 14400, 19200 bps
Data length
8 bit
Start bit
1 bit
Stop bit
1 bit
Parity
None
Flow control
None
. Output elements : Instantaneous wind direction, Instantaneous wind speed, Instantaneous
maximum wind speed, Instantaneous minimum wind speed, Mean wind direction,
Mean wind speed, Mean maximum wind speed, Mean minimum wind speed,
Operation status, Monitoring of DC power input
. Transmission interval: 0.25, 0.5, 1, 5, or 10 sec.
7. Distance measured
: within 300m (used with CVVS1.25mm
2
cable)
8. Operation ambient
: 0 to 50°C, less than 90%RH (no condensing)
9. Body
: Desk-top type with rubber feet and a tilting stand
Material: steel plate,
10. Power requirements
: 100VAC±10%, 50/60Hz, approx. 20VA
11. Outer Dimensions/Weight : approx. 200mm (W) x 110mm (H) x 200mm (D)
approx. 3.5kg