17
III-9. Initial Settings (Default settings)
Mode code
Description
Setting value
1
a1 (A1)
Wind speed alarm criteria
Instantaneous wind speed
2
a2 (A2)
Wind speed alarm 1 setting value
10 (m/s)
3
a3 (A3)
Wind speed alarm 2 setting value
20 (m/s)
4
a4 (A4)
Wind speed alarm 3 setting value
30 (m/s)
5
a5 (A5)
Setting value for the wind speed alarm
confirmation time
1 (sec)
6
a6 (A6)
Setting value for the wind speed alarm
cancellation time
3 (sec)
7
a7 (A7)
Wind direction alarm criteria
No wind direction
(No alarm output)
8
a8 (A8)
Wind direction alarm section 1, start point
setting value
0 (°)
9
a9 (A9)
Wind direction alarm section 1, end point setting
value
0 (°)
10
a0 (A0)
Wind direction alarm section 2, start point
setting value
0 (°)
11
b1
Wind direction alarm section 2, end point setting
value
0 (°)
12
b2
Setting value for the wind direction alarm
confirmation time
5 (sec.)
13
b3
Setting value for the wind direction alarm
cancellation time
5 (sec.)
14
b4
Display item in the upper wind speed display
section
Instantaneous wind speed: fixed
15
b5
Display item in the lower wind speed display
section
Mean wind speed: fixed
16
b6
Display item in the wind direction display section
Instantaneous wind direction
17
-
Wind speed & direction display update time
1 (sec.): fixed
18
-
Wind speed & direction instantaneous value
processing
Instantaneous value
19
-
Wind speed & direction mean value processing
time
10 (min.)
20
-
Timer for alarm buzzer sounding time
Automatic stop is not performed
21
-
Alarm contact output logic
When alarm outputs Contact ON
22
-
CH1 Analog output criteria
Instantaneous wind speed
23
-
CH1 Analog output span
90 (m/s)
24
-
CH2 Analog output criteria
Instantaneous wind direction
25
-
CH2 Analog output span
0 to 540 (°)
26
-
Digital (RS-422) output transmission speed
19200 (bps)
27
-
Digital (RS-422) output transmission interval
1 (sec.)
* If you do not have specified settings at the time of ordering, we will ship the unit with initial settings.
No. 17 to 25 are internal setting items. When you want to inquire about the setting change, please
contact us or the shop from which purchased.
III-10. Accessories: Fuse (rating: 125VAC 1A) 5.2dia x 20mm: 2 pcs.