SATELLINE-3AS and SATELLINE-3ASd
35
6.2.3
Serial port settings
Press
ý
or
þ
until
the cursor points to
the correct port (Port
1 or Port 2) and
press Setup
RF frequency
Addressing
>Port 1
Port 2
Additional
Test
Factory setup
Contrast
CANCEL ýþ Setup
Press
ý
or
þ
until the
cursor points to the
parameter you wish
to change and
press Change
>ON
19200 bit/s
8 bit data
None parity
1 stop bit
CANCEL ýþ Change
Port status selection:
Press
ý
or
þ
until the cursor points to the
correct status.
To set correct port on, press set Note: The
cursor position initially indicates the
current setting
>P1 ON / P2 OFF
P1 OFF / P2 ON
CANCEL ýþ SET
Data speed selection:
Press
ý
or
þ
until the cursor points to the
correct value and then press set
Note: The cursor position initially indicates
the current setting
300 bit/s
600 bit/s
1200 bit/s
2400 bit/s
4800 bit/s
9600 bit/s
>19200 bit/s
38400 bit/s
CANCEL ýþ SET
Number of data bits selection:
Press
ý
or
þ
until the cursor points to the
correct value and then press set
Note: The cursor position initially indicates
the current setting
7 bit data
>8 bit data
9 bit data
CANCEL ýþ SET
Parity selection:
Press
ý
or
þ
until the cursor points to the
correct value and then press set
Note 1: The cursor position initially
indicates the current setting
Note 2: If the number of data bits is 9,
parity has to be none
Even parity
>None parity
Odd parity
CANCEL ýþ SET
Number of stop bits selection:
Press
ý
or
þ
until the cursor points to the
correct value and then press set
Note: The cursor position initially indicates
the current setting
>1 stop bit
2 stop bit
CANCEL ýþ SET