SATEL PERFECTA
17
SMS notifications confirming ev.
[Messaging events] – if this option is enabled, information
about sending SMS notification is saved in the event log.
Zone restore events
[Restore events] – when this option is enabled, information about zone
restore is saved in the event log, if zone triggered alarm.
Limit number of events
[Events limitat.] – if the option is enabled, events from the same
source are saved into the event log 3 times only. This option does not apply to the alarms
from zones.
Grade 2
[Grade 2] – if the option is enabled, the system operates in accordance with the EN
50131 standard requirements for Grade 2, i.e.:
– the keypad does not audibly signal alarms and troubles,
– the
LEDs on the keypad indicates alarms only after the user enters the code and
presses
,
– the
LED on the keypad goes off after just one of the partitions is armed in any
mode,
– the flashing
LED in keypad means that there is a trouble in the system, some zones
are bypassed, or there has been an alarm,
– the keypad does not display alarm messages,
– the keypad display cannot be switched over to the zone status presentation mode,
– the quick arming from keypad (without entering the code) is not available,
– new access codes in the system must be composed of at least 5 digits,
– partial entering of the code is interpreted as entering an incorrect code,
– the keypad will be blocked after entering an incorrect code three times (cf. B
LOCK AFTER
THREE INCORRECT CODES
option),
– during arming, the control panel checks for problems that prevent arming (cf. P
REVENT
ARMING IF NOT READY
option),
– A
RM EVEN IF NOT READY AFTER EXIT DELAY
, D
O NOT ARM IF BATTERY TROUBLE
and D
O NOT
ARM IF TAMPERED
options are interpreted as disabled,
– control panel gives information about past troubles (cf. T
ROUBLE MEMORY
option),
– loss of communication with SATEL server will not be reported (cf. D
O NOT REPORT A
SATEL
SERVER PROBLEM
option),
– tamper of zone or expander can only be signaled by the external siren when the
partition to which the zone or expander belong is armed,
– the number of alarms from the 7. 24
H
P
ANIC
and 8. 24
H
P
ANIC SILENT
zones is not limited
(A
UTO
-
RESET
3 option is ignored),
– arming is impossible, if the 6. 24
H
T
AMPER
zone is violated (cf. P
RIORITY
option),
– the warning alarm feature is enabled and the warning alarm is being signaled for at
least 30 seconds (cf. W
ARNING TIME
),
– countdown of E
NTRY DELAY
, D
ELAY
and D
ELAY ACTIVATION TIME
is running for up to 45
seconds,
– AC loss report delay can be up to 60 minutes.
Tamper alarm on internal sirens
[Tmp.on int.siren] – if this option is enabled, the
1. I
NTERNAL SIREN
output is additionally activated after triggering tamper alarm.
Tamper alarm on external sirens
[Tmp.on ext.siren] – if this option is enabled, the
1. E
XTERNAL SIREN
output is additionally activated after triggering tamper alarm.
Backlight off on AC loss
[No AC=no bcklght] – if the option is enabled, the backlight in
hardwired keypads is automatically switched off in case of 230 V AC power loss.