background image

CONTROL BOARD 

MC101

USER / INSTALLER MANUAL

ÍNDEX ◁

00

CONTENT

01. SAFETY INSTRUCTIONS

 

▷ standards to follow   

| page 01.B

02. THE CONTROL BOARD

 

▷ technical specifications   

| page 01.B

 

▷ dippers function   

| page 01.B

 

▷ connectors   

| page 02.A

03. CONFIGURATION

 

▷ transmmiter’s configuration  

| page 02.B

 

▷ functionalities   

| page 03.A

 

▷ instalation process   

| page 03.B

   

04. DIAGNOSIS

 

▷ failures diagnosis 

| page 04.A

 

▷ motor diagnosis   

| page 04.A

05. CONNECTION SCHEME

 

▷ component connection to the control board 

| page 04.B

v1.0

REV. 05/2014

1

ON

2

3

4

Summary of Contents for MC101

Page 1: ...ifications page 01 B dippers function page 01 B connectors page 02 A 03 CONFIGURATION transmmiter s configuration page 02 B functionalities page 03 A instalation process page 03 B 04 DIAGNOSIS failures diagnosis page 04 A motor diagnosis page 04 A 05 CONNECTION SCHEME component connection to the control board page 04 B v1 0 REV 05 2014 1 ON 2 3 4 ...

Page 2: ...ust inform the client how to handle the product in case of emergency and provide this manual to user Keep remote controls away from children to prevent the automated system from being activated involuntarily The customer shall not under any circumstances attempt to repair or tune the automatism Must call qualified technician only Connect the automatism to a 230Vplug with ground wire Control board ...

Page 3: ...g to the control board configuration please note the following points listed in the table below in order to better understand the control board function Button 1 Button 2 Button 3 Button 4 MX4SP Button 1 Button 2 Button 3 Button 4 MXS4SP New transmitters configuration 2 keys DIP 2 ON 1 Press the P1 button once and the LED CODE will light during 6sec 2 While the CODE LED is light up press the openi...

Page 4: ...must enable auto locking by putting DIP1 ON For each pulse in the P2 button with the motor opened in pause time the CODE LED will flash one time for 30sec two times for 60sec and three times to 90sec NOTE The Working Time should be set to a value above the actual required working time For example if the automatism needs 40sec to go all the course you must set the Working Time for 60sec Setting the...

Page 5: ... in the control board If the engine is running connected to a power source it means that the problem is in another component such as control board or power supplies All tests must be performed by professional technicians due to serious danger associated with the misuse of electrical systems To detect which components have problems in an installa tion it is sometimes necessary to perform a test wit...

Reviews: