SATEL PERFECTA
25
The exit delay countdown can be terminated by using keypad (see E
XIT DELAY
CLEARING ENABLE
option) or zones of the 1.
E
NTRY
/E
XIT FINAL
, 16.
E
XIT
D
ELAY
T
ERMINATOR
or 17. S
HUNT
L
OCK
type.
Warning time
[14.Warn.delay] – duration of the warning alarm. You can enter from 0 to 255
seconds. Entering any value different from 0 means enabling the warning alarm feature.
The alarm alerts the user that he or she has forgotten to disarm the partition. The warning
alarm is triggered when:
– E
NTRY DELAY
time has elapsed (see: p. 27),
–
DELAY
time has elapsed (see: p. 27),
– 3. I
NSTANT
or 4. D
OUBLE KNOCK
zone triggered alarm when E
NTRY DELAY
countdown was
running.
The warning alarm can be signaled by keypad or 2. I
NTERNAL SIREN
type output. It is not
reported. If the partition is not disarmed during the warning alarm, the burglary alarm will
be triggered.
Alarm verif. time
[15.Verif.delay] – time for verification of the alarm. You can enter from 0 to
255 minutes. Entering any value different from 0 means activation of the burglary alarm
verification function. The verification consists in checking whether another zone will trigger
the burglary alarm within the defined period of time. If so, the verified alarm will be
generated. Alarms from the 0. E
NTRY
/E
XIT
, 1. E
NTRY
/E
XIT FINAL
, 2. I
NTERNAL
, 3. I
NSTANT
,
4. D
OUBLE KNOCK
or 5. 24
H
B
URGLARY
zones are verified. The time is counted from the
moment of alarm triggering by this type of zone.
Exit delay clearing enable
[Fin.exit delay] – if this option is enabled, the users can terminate
the exit delay countdown by using keypad (the
,
or
key is to be pressed
and hold down for about 3 seconds).
Infinite exit delay
[Infinit.ex.delay] – if this option is enabled, the exit delay time is infinite. It
can be terminated:
– on violation of the 1. E
NTRY
/E
XIT FINAL
, 16. E
XIT
D
ELAY
T
ERMINATOR
or 17. S
HUNT
L
OCK
type zones,
– after pressing and holding down for 3 seconds the
,
or
keys on the
keypad (when the E
XIT DELAY CLEARING ENABLE
option is enabled).
If the exit delay countdown is not terminated, the partition will not be armed.
6. Zones
A zone can be assigned to one or two partitions. If the zone is assigned to two partitions, it
can be armed when both partitions are armed or one of them only.
The system supports the following zones:
hardwired – on the control panel PCB and in expanders. The number of available
hardwired zones is determined by the control panel during the identification procedure.
wireless – in the PREFECTA 16-WRL or PERFECTA 32-WRL control panel, after adding
wireless detectors. The number of available wireless zones depends on the number of
wireless detectors registered in the system.
virtual – zones which do not physically exist, but are controlled by means of keyfobs.