26 PERFECTA
SATEL
6.1 Zone parameters and options
Fig. 14. “Zones” tab.
Name
[38.Names] – individual name of zone (up to 16 characters).
Wiring type
[31.EOL] – type of detector and the method of its connection:
No detector
– no detector is connected to the zone,
NC
– the zone supports a detector of NC (normally closed) type,
NO
– the zone supports a detector of NO (normally open) type,
EOL
– the zone supports a detector of NO or NC type with EOL resistor in the circuit,
2EOL/NO
– the zone supports a detector of NO type with two EOL resistors in the circuit,
2EOL/NC
– the zone supports a detector of NC type with two EOL resistors in the circuit,
Roller
– the zone supports a roller shutter detector,
Vibration
– the zone supports a vibration detector (also NC type detector).
In case of the V
IBRATION
wiring configuration, opening the circuit for 200 ms or longer –
irrespective of the programmed number of pulses and sensitivity (see below) – will be
interpreted as violation. This solution enables a magnetic contact to be connected in
series with the vibration detector.
Sensitivity
[32.Sensitivity] – depending on wiring type:
NO, NC, EOL and 2EOL
– the time during which the zone must be violated, so that it can
be noted by the control panel. The sensitivity is programmed in milliseconds. You can
enter values from the 20 ms to 5100 ms range.
Vibration
– the pulse whose duration is equal to or longer than the defined time will cause
violation of the zone. You can enter values from the 5 ms to 160 ms range (every 3 ms).
Pulses
[32.Sensitivity] – the number of pulses after which the zone will be violated. The
parameter applies to the R
OLLER
and V
IBRATION
wiring configurations. For the V
IBRATION
wiring configuration you can enter values from 0 to 7 (for the value 0, the pulses will not be
counted, the S
ENSITIVITY
parameter only being taken into account). For the R
OLLER
wiring
configuration you can enter values from 1 to 8.