14 MTX-300
SATEL
Fig. 7. “Inputs/sirens” tab.
6.4 Description of parameters and options
Output cutoff time
– time during which the relay output will be on. You can program 8
different cutoff times ranging from 1 second to 99 minutes 59 seconds [minutes:seconds].
Additionally, 4 non-editable cutoff times are available.
Maximum no-communication time
– if the period of no communication with a detector or
siren exceeds the preprogrammed time, the FTR output will turn on (“Presence control”
option must be enabled for the detector or siren). You can program the time within the
range of 20 minutes to 49 hours 50 minutes [hours:minutes].
After a new “Maximum no-communication time” value has been programmed in the
service mode, a restart of the presence control function will follow.
Maximum signaling time
– signaling will be stopped automatically by the siren after the
preprogrammed time has elapsed (even if the input is still on). The parameter is to be
programmed individually for each siren. You can program the time within the range of 10
seconds to 3 minutes [minutes:seconds].
NO / NC
– inputs / outputs can work as NO (normally open) or NC (normally closed).
Priority
– option available for inputs. If the option is enabled, the input will always trigger
signaling, i.e. even when signaling triggered by the other input is taking place (that
signaling will be stopped). If the option is disabled, the input will not trigger any signaling,
as long as signaling triggered by the other input is taking place.
Presence control
– if the option is enabled, availability of detector / siren is monitored (see
“Maximum no-communication time”).
Name
– individual name of the input, output or wireless device. You can only program the
name using the MTX
S
OFT
program.