23
Configuration of all inputs and outputs: NO
1. output cutoff time: 3 minutes
2. output cutoff time: 6 minutes
3. output cutoff time: 10 minutes
4. output cutoff time: 15 minutes
5. output cutoff time: 30 minutes
6. output cutoff time: 45 minutes
7. output cutoff time: 60 minutes
8. output cutoff time: 90 minutes
Maximum no-communication time: 1 hour 10 minutes
Maximum signaling time (for each siren): 10 seconds
No registered wireless devices
Inputs do not trigger signaling
Priority option enabled for inputs
8.1 Restoring default settings
Restoring the default factory settings means removal of all registered wireless devices.
If wireless sirens are registered in the controller, they must be deleted before restoring
the default settings.
8.1.1 Using buttons
1. Power off the controller.
2. Press simultaneously the
and
buttons and power on the controller.
3. Hold the and
buttons down for about 4 seconds.
4. When
is displayed, press the
button.
5. This will enter the service mode (the
function will be displayed).
8.1.2 Using MTX soft program
Click “Communication”
“Manufacturer settings”.
9. Specifications
Supply voltage ................................................................................................... 12 V DC ±15%
Standby current consumption ..........................................................................................65 mA
Maximum current consumption........................................................................................70 mA
Operating frequency band .......................................................................433.05 ÷ 434.79 MHz
Radio communication range (in open area) .............................................. depending on device
Relay output rating (resistive load) ................................................................. 60 mA / 30 V DC
OC type output rating...................................................................................... 50 mA / 12 V DC
Environmental class according to EN50130-5 ......................................................................... II
Operating temperature range.............................................................................-10 °C...+55 °C
Maximum humidity..........................................................................................................93±3%
Enclosure dimensions..................................................................................126 x 158 x 32 mm