Prior to putting the unit/spray gun into operation, read the oper-

ating instructions completely and thoroughly. The stipulations 

contained therein are to be respected in any case. After that, the 

operating instructions are to be stored in a safe place, accessible 

for every user of the equipment. The unit/spray gun may only be 

put into operation by persons familiar with its use (professionals). 

Inappropriate use of the unit/spray gun, modification of any kind 

or combination with inappropriate other parts may cause material 

damage, serious hazard to the user‘s, other person‘s or animal‘s 

health or even death. SATA shall not take any responsibility for 

such damages (e.g. failure to respect the stipulations laid out in 

the operating instructions). The applicable safety, workplace and 

worker health protection regulations of the respective country or 

area/district in which the system/the spray gun is used are to be 

respected in any case (e.g. the German Rules for the Prevention 

of Accidents BGR 500 (BGV D25) and BGV D24 issued by the 

Central Office of the Professional Trade Associations, etc.).

2. Functional Description

The breathing air purified in advance filters or, additionally, in the 

belt unit is fed into the humidifier by the compressed air supply 

hose (1). Upon streaming through the humidifier's diaphragm 

module (3), the air becomes automatically saturated with mois-

ture. The purified and humidified breathing air is ready to be sup-

plied to a full face or half mask respirator, by the outlet coupling 

(11). While air is passing through the SATA breathing air humidi-

fier top air, there is no pressure drop, resp. no remarkable air 

loss. The water contained in the water storage (4) automatically 

penetrates the diaphragm threads of the humidifier module (3), 

always in a precisely sufficient quantity for optimum saturation 

of the air. If there is no air stream through the humidifier, water 

flow from outside to inside is interrupted, and therefore droplet 

formation is prevented.

3. Putting into Operation

When putting the unit into operation for the first time, or after long 

breaks (several days), the water storage (4) must be filled while 

being in a vertical position until the maximum filling level (5), after 

removing the closing screw of the filling opening. After this, wait 

for 20 minutes to allow the diaphragm threads to become satu-

rated with water and reach their maximum mechanical stability. 

In case the unit is put into operation too early, without waiting 

time, the diaphragm threads may be damaged, and water may 

penetrate in an uncontrolled way into the air passages. Always 

fill the SATA top air humidifier while the unit is in vertical position. 

Upon reaching the maximum filling level (5), insert and tighten 

again closing screw of the filling opening. After the 20 minutes' 

waiting time, connect the unit to the belt unit by the air supply 

hose (1), while the respirator is already coupled.

Attention:

 The outlet coupling for respirator connection is 

no self-shut coupling, to avoid non-permissible pressure rise 

inside the humidifier when the respirator is disconnected. This 

means that in case the respirator is disconnected, the entire air 

is freely released at the coupling. Therefore always disconnect 

the humidifier from the belt unit and air supply hose (1) first, and 

then, if necessary, the respirator from the humidifier (the belt unit 

features a self-shut coupling which automatically interrupts the 

air stream).

Attention: 

All couplings are safety couplings. Therefore the nip-

ple must be pressed tight into the coupling for disconnection. 

Simultaneously the sleeve must be shifted back. Since the outlet 

coupling of the SATA top air is not self-shutting, for reasons 

described above, always connect respirator first to the humidi-

fier, when putting the unit into operation, before the appliance 

is connected to the regulation valve / belt unit. After this adjust, 

as usual, the required air volume at the belt unit resp. regulation 

valve. No further steps need to be taken at the humidifier itself.

4. Water Quality

To ensure sufficient life time of the humidifier module and to obtain 

sufficient humidifying performance, use distilled water exclusively. 

Attention:

 In no case anesthetic or similar materials may be 

filled into the humidifier. This also applies for distilled oils etc., 

since their effects in the breathing air may harm the equipment 

wearer.

5. Safety Valve

The handle (8) features a built-in safety valve in order to prevent 

destruction of the humidifier module by non-permissible pressure 

rise. The safety valve in particular helps to prevent uncontrolled 

pressure rise when the breathing air hose leading to the respira-

tor becomes kinked. It is set to maximum 3 bars (43 psi) which 

is never exceeded. This pressure is sufficient for the operation 

of all SATA respirators, and therefore for ensuring maximum air 

supply.

Note: 

If the safety valve is activated, check the air pressure in 

the hose feeding the respirator, or the air hose leading to the res-

pirator for possible kinking. If necessary, remove kinks, replace 

breathing air hose or reduce air feed pressure.

5. Pressure Release

As the threads of the humidifier module can be penetrated by 

water, a small amount of air from the diaphragm inside will also 

get into the water storage. In order to ensure this area is always 

devoid of pressure when the humidifier has been disconnected, 

the handle also features a built-in pressure release (11) which 

helps to ventilate the water storage and to shift all air pressure 

into the humidifier diaphragm area. Make sure the hose between 

pressure release and nipple is never kinked.

Attention:

 Always make sure the humidifier is in a vertical posi-

tion when being disconnected, to prevent water from the storage 

from penetrating, by means of the pressure release function, into 

the air passages of the system.

7. Changing the Water

Depending on the air flow, the water is usually used up after 3 

hours of work. If warm water is filled in, the breathing air temper-

ature may be raised. However, never fill water with a temperature 

of more than 60° C into the unit in order to avoid scalding or 

similar problems, resp. damage to the unit. When the unit is not 

in use for a long period of time (several days, etc.), it must be 

emptied in order to prevent germ infestation, fouling of water, etc. 

Make sure the different parts (humidifier module, etc.) can dry off 

completely. If necessary blow-dry the pressure release unit from 

the inside of the handle (8) by means of compressed air.

8. Changing the Humidifier Module

The humidifier module is to be changed every six months 

in order to prevent germ infestation. It may be necessary to 

change the humidifier module earlier if no distilled water is used, 

or if the diaphragm threads are damaged. This damage can 

be recognized by non-permissible water penetration into the 

air hose leading to the respirator. For changing the humidifier 

module unscrew the receptacle (7) from the handle (8) after the 

appliance has been emptied completely, and pull the humidifier 

Delivery Volume

Art. No. 89086 cpl., with refill bottle (Art. No. 34751)
Pression maximale:

3 bar

Max. operating temperature:

60° C

Min. operating temperature:

+4° C

Filling quantity:

130 ccm

Weight (empty):

378 g

EN

51052-BAL SATA top air.indd   4

02.07.2013   08:51:21

Summary of Contents for top air

Page 1: ...1 3 Module humidificateur 1 4 R cipient d eau 1 5 Niveau minimum de remplissage 1 6 Niveau maximum de remplissage 1 7 R cipient d tachable 1 8 Support pour tre branch la ceinture 1 9 Vis de fermeture...

Page 2: ...ebeh lse zur ckschieben Da die Abgangskupplung am SATA top air aus dem funktions beschriebenen Gr nden nicht selbstschlie end ist ist bei Inbe triebnahme der Atemanschlu immer vor dem Ankuppeln des Lu...

Page 3: ...n der Innenseite des Halters 8 her trocken zu blasen um diese Keimbildung zuverl ssig zu verhindern 10 Bef llungshilfe Vorteilhafterweise l t sich das SATA top air mit einer Kunst stofflasche mit ents...

Page 4: ...le must be pressed tight into the coupling for disconnection Simultaneously the sleeve must be shifted back Since the outlet coupling of the SATA top air is not self shutting for reasons described abo...

Page 5: ...SATA top air can be easily refilled by means of a plastic bottle with a correspondingly thin neck Bottles with a filling tip or arched neck are especially suitable see SATA Art No 34751 11 Guarantee c...

Page 6: ...ude la quantit d air d sir e l unit de ceinture valve de r glage Il n est pas n cessaire de faire des ajustages quelquonques l humidificateur lui m me Attention Ne jamais utiliser l appareil une temp...

Page 7: ...c une tubulure de remplissage ou un cou ploy voir SATA r f 34751 11 Conditions de garantie Pour ce genre d appareil nous offrons une garantie de 12 mois dater du jour de l achat par l utilisateur fina...

Page 8: ...uyau souple 63214 Vis de fermeture 70789 Joint torique 5 x 2 72611 Valve cpl 81158 Module cpl 82917 Tuyau d air respirable cpl 97311 Tuyau d air en PVC 4 x 2 mm 163535 Dispositif 163543 R cipient 1764...

Reviews: