252
US
Operating Manual SATA filter 100 / 101 / 103 prep
Information!
• Mount compressed air connector G ¼" (interior thread) or matching
SATA-quick-action coupling G ¼
"
(interior thread) (item no. 13599,
not included in delivery) on the ball tap
[1-6]
.
• For regular filter maintenance, replace and activate the SATA filter
timer of the respective filter stage (sintered filters and fine filters every
6 months, activated carbon filters every 3 months).
1. Connect suitable compressed air hose.
2. Turn the pressure adjustment knob
[1-5]
in counterclockwise direction
to the maximum; state = closed
3. Fully open ball valve
[1-6]
4. Turn pressure adjustment knob
[1-5]
to the right until required pres-
sure is displayed on the pressure gauge
[1-3]
.
5. Control pressure when operating the spray gun (trigger fully pulled)
and re-adjust, if necessary.
9. Function
9.1. Filter stage [A]:
The first filter stage separates particles > 5 µm as well as condensed wa-
ter and oil. The sintered filter
(Art. No. 22160)
is integrated in the filter.
Information!
Sintered filter:
• Fineness 5µm
• Surface 100 cm²
The automatic condensate drain valve
[1-9]
only works properly when the
filter is vertically mounted. If a certain condensate filling level is reached
inside the filter housing
[1-12]
, the condensate drain valve opens auto-
matically draining the condensate through the condensate drain hose
[1-
10]
into the collection container (not included in delivery) until just a small
residual quantity remains.
9.2. Filter stage [B]:
The fine filter cartridge
(Art. No. 148270)
of the second filter stage sepa-
rates smallest particles.
BAL-SATA filter 100-101-103 prep.indb 252