Operating Manual SATA filter 100 / 101 / 103 prep
Malfunction
Cause
Corrective action
Traces of compressor
oil in the compressed
air
Too much oil in the
compressed air
Control compressor,
refrigerated dryer
Drain condensate
(open manually)
Saturated filter
Filter maintenance
required, chapter 10
No or insufficient con
-
densate drainage (a
minimum condensate
level is required as it
serves to lift the floater
and, thus, to open the
drain valve)
Floater stuck on the
drain valve
Disassemble drain
valve by removing the
safety disc, then clean
or exchange drain
valve
Damaged drain valve
Exchange drain valve
Art. No. 15511
Drain valve blows
permanently (never
disassemble the drain
valve itself, risk of
damage)
Filter is not installed
vertically
Install filter vertically
Pressurised brass
component has not
been completely
turned to the left (an
-
ti-clockwise direction).
Pressurise filter and
open knob of the brass
component to the max-
imium in anti-clockwise
direction
Floater stuck on the
drain valve
Remove drain valve
and clean or exchange
it
Damaged drain valve
Exchange drain valve
Art. No. 15511
Internal filter pressure
< 1 bar
Increase inlet pressure
12. Disposal
The oil and condensate free filter has to be disposed of as recycable
waste. Please observe local regulations!