Operating Manual SATA filter 100 / 101 / 103 prep
Danger! Notice!
•
When the compressed air is heavily contaminated, the filter
cartridges have to be exchanged in shorter intervals!
• Saturated filter cartridges may cause quality problems during paint
jobs. Furthermore, using a supplied-air respirator could become harm-
ful, causing permanent health damage and even death!
• Depressurize filter (close shut-off tap)
• Unscrew
[3]
the respective filter housing with the pin spanner included
in the delivery.
• Remove condensate cyclone separator
[4-1]
from the filter stage
[A]
, remove and check insert as well as sintered filter
[4-2]
. Clean or
replace if necessary
• Remove
[4-3]
and replace fine or activated charcoal cartridge on filter
stages
[B]
and
[C]
• Installation has to be carried out in reverse order. Please make sure
that the filter cartridges are installed in the correct order. Coloured
markers (yellow = sintered filter
[A]
, blue = fine filter
[B]
, black = acti-
vated charcoal filter
[C]
allow clear identification
[4-4]
. Marking rings
are located on the threaded rods of the filter stages
[B]
and
[C]
.
• During installation, please ensure proper seat and undamaged O-rings!
Information!
Please observe local regulations for the disposal of filter cartridges!
11. Troubleshooting
Malfunction
Cause
Corrective action
Pressure cannot be
properly adjusted
Insufficient inlet pres-
sure
Increase inlet pressure
Pressure regulation
valve at air outlet mod-
ule is defective
Exchange air outlet
module [D], Art. No.
148239