SATA top air | 5

Delivery Volume

Art. No. 89086 cpl., with refill bottle (Art. No. 34751)
Pression maximale:

3 bar

Max. operating temperature:

60° C

Min. operating temperature:

+4° C

Filling quantity:

130 ccm

Weight (empty):

378 g

1.  Technical Design

[1-1]  Air supply hose, coming from belt unit (regulation valve)

[1-2]  Air inlet nipple

[1-3]  Humidifier module

[1-4]  Water storage

[1-5]  Minimum filling level

[1-6]  Maximum filling level

[1-7]  Removable receptacle

[1-8]  Handle for clamping the unit to the carrying belt

[1-9]  Closing screw for filling opening

[1-10] Safety valve

[1-11] Outlet coupling for connecting full face or half mask 

respirator

[1-12] Pressure relief valve

[1-13] Anti-bend spring

Prior to putting the unit/spray gun into operation, read the 

operating instructions completely and thoroughly. The stipula-

tions contained therein are to be respected in any case. After 

that, the operating instructions are to be stored in a safe place, 

accessible for every user of the equipment. The unit/spray gun 

may only be put into operation by persons familiar with its use 

(professionals). Inappropriate use of the unit/spray gun, modifi-

cation of any kind or combination with inappropriate other parts 

may cause material damage, serious hazard to the user‘s, 

other person‘s or animal‘s health or even death. SATA shall 

not take any responsibility for such damages (e.g. failure to 

respect the stipulations laid out in the operating instructions). 

The applicable safety, workplace and worker health protection 

regulations of the respective country or area/district in which 

the system/the spray gun is used are to be respected in any 

case (e.g. the German Rules for the Prevention of Accidents 

DGUV-R 100-500 and DGUV-R 109-002 issued by the Central 

Office of the Professional Trade Associations, etc.).

2. Functional Description

The breathing air purified in advance filters or, additionally, in 

the belt unit is fed into the humidifier by the compressed air 

supply hose (1). Upon streaming through the humidifier's dia-

phragm module (3), the air becomes automatically saturated 

with moisture. The purified and humidified breathing air is 

ready to be supplied to a full face or half mask respirator, by 

the outlet coupling (11). While air is passing through the SATA 

breathing air humidifier top air, there is no pressure drop, resp. 

no remarkable air loss. The water contained in the water stor-

age (4) automatically penetrates the diaphragm threads of the 

humidifier module (3), always in a precisely sufficient quan-

tity for optimum saturation of the air. If there is no air stream 

through the humidifier, water flow from outside to inside is 

interrupted, and therefore droplet formation is prevented.

3. Putting into Operation

Before using the PPE breathing protection equipment, every 

user is obliged to check the capacity of the air supply system, 

possibly also in terms of the impact on other users of the sys-

tem.

The code "H" indicates that the compressed air feed tube is 

heat-resistant. The code "S" indicates that the compressed air 

feed tube is antistatic.

Before operation, the user must proceed with a risk assess-

ment regarding possible harmful components in the workplace, 

e.g. nitrogen. 

When putting the unit into operation for the first time, or after 

long breaks (several days), the water storage (4) must be filled 

while being in a vertical position until the maximum filling level 

(5), after removing the closing screw of the filling opening. 

After this, wait for 20 minutes to allow the diaphragm threads 

to become saturated with water and reach their maximum 

mechanical stability. In case the unit is put into operation too 

early, without waiting time, the diaphragm threads may be 

damaged, and water may penetrate in an uncontrolled way into 

the air passages. Always fill the SATA top air humidifier while 

the unit is in vertical position. Upon reaching the maximum fill-

ing level (5), insert and tighten again closing screw of the filling 

opening. After the 20 minutes' waiting time, connect the unit to 

the belt unit by the air supply hose (1), while the respirator is 

already coupled.

Attention: 

The outlet coupling for respirator connection is 

no self-shut coupling, to avoid non-permissible pressure rise 

inside the humidifier when the respirator is disconnected. This 

means that in case the respirator is disconnected, the entire 

air is freely released at the coupling. Therefore always discon-

nect the humidifier from the belt unit and air supply hose (1) 

first, and then, if necessary, the respirator from the humidifier 

(the belt unit features a self-shut coupling which automatically 

interrupts the air stream).

Attention: 

All couplings are safety couplings. Therefore the 

nipple must be pressed tight into the coupling for disconnec-

tion. Simultaneously the sleeve must be shifted back. Since 

the outlet coupling of the SATA top air is not self-shutting, for 

reasons described above, always connect respirator first to 

the humidifier, when putting the unit into operation, before the 

appliance is connected to the regulation valve / belt unit. After 

this adjust, as usual, the required air volume at the belt unit 

resp. regulation valve. No further steps need to be taken at the 

humidifier itself.

4. Water Quality

To ensure sufficient life time of the humidifier module and to obtain 

sufficient humidifying performance, use distilled water exclusively. 

Attention:

 In no case anesthetic or similar materials may be 

filled into the humidifier. This also applies for distilled oils etc., 

since their effects in the breathing air may harm the equipment 

wearer.

5. Safety Valve

The handle (8) features a built-in safety valve in order to pre-

vent destruction of the humidifier module by non-permissible 

pressure rise. The safety valve in particular helps to prevent 

uncontrolled pressure rise when the breathing air hose leading 

to the respirator becomes kinked. It is set to maximum 3 bars 

(43 psi) which is never exceeded. This pressure is sufficient for 

the operation of all SATA respirators, and therefore for ensur-

ing maximum air supply.

Note: 

If the safety valve is activated, check the air pressure 

in the hose feeding the respirator, or the air hose leading to 

the respirator for possible kinking. If necessary, remove kinks, 

replace breathing air hose or reduce air feed pressure.

5. Pressure Release

As the threads of the humidifier module can be penetrated by 

water, a small amount of air from the diaphragm inside will 

also get into the water storage. In order to ensure this area is 

always devoid of pressure when the humidifier has been dis-

connected, the handle also features a built-in pressure release 

(11) which helps to ventilate the water storage and to shift all 

air pressure into the humidifier diaphragm area. Make sure the 

hose between pressure release and nipple is never kinked.

Attention:

 Always make sure the humidifier is in a vertical 

position when being disconnected, to prevent water from the 

storage from penetrating, by means of the pressure release 

EN

Summary of Contents for 34751

Page 1: ...ntents Original Version German 1 Technical Design 2 Functional Description 3 Use 4 Water Quality 5 Safety Valve 6 Pressure Release 7 Changing the Water 8 Changing the Humidifier Module 9 Germ Infestat...

Page 2: ...m maxi malen F llstand zu bef llen Danach das Ger t ca 20 Minuten stehen lassen damit die Membranf den sich mit dem Wasser s ttigen k nnen und ihre mechanische Stabilit t erreichen Bei zu schneller In...

Page 3: ...Keimbildung zuverl ssig zu verhindern 10 Bef llungshilfe Vorteilhafterweise l t sich das SATA top air mit einer Kunst stofflasche mit entsprechendem d nnem Bef llhals bef llen Geeignet sind hierzu z B...

Page 4: ...Verordnungen erkl rt Richtlinie 2014 34 EU PSA Benutzungsverordnung PSA BV Verordnung ber Si cherheit und Gesundheitsschutz bei der Benutzung pers nli cher Schutzausr stungen bei der Arbeit DIN EN 112...

Page 5: ...moving the closing screw of the filling opening After this wait for 20 minutes to allow the diaphragm threads to become saturated with water and reach their maximum mechanical stability In case the un...

Page 6: ...4751 11 Guarantee conditions During the period of twelve 12 months from the date of original purchase SATA will repair or replace the product without charge for parts or labour subject to the followin...

Page 7: ...1 Basic con cepts and methodology DIN EN 80079 36 Non electrical equipment for explosive atmospheres Part 1 Basic method and requirements DIN EN ISO 12100 Safety of machinery general require ments Ad...

Page 8: ...mum Apr s cela attendre environ 20 minutes pour permettre aux membranes de se saturer afin d atteindre leur stabilit maximale Si l appareil est mis en marche trop t t il y a le danger d un endommage m...

Page 9: ...ppareil nous offrons une garantie de 12 mois dater du jour de l achat par l utilisateur final La garan tie s applique la valeur mat rielle de pi ces ayant un d faut de fabrication ou de mat riau se r...

Page 10: ...de s curit et de protection de la sant en utilisant des quipements de pro tection individuelle en travaillant DIN EN 1127 1 Pr vention de l explosion partie 1 no tions fondamentales et m thodologie D...

Page 11: ...top air 11 89086 34751 3 60 C 4 C 130 378 1 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 1 10 1 11 1 12 1 13 SATA DGUV R 100 500 DGUV R 109 002 2 1 11 SATA top air 4 3 H S 9 20 20 1 SATA top air 4 C 4 5 8 10 3...

Page 12: ...SATA top air 12 6 11 7 3 60 C 8 8 7 8 3 8 SATA 48173 SATA 48173 9 11 8 10 SATA top air SATA 34751 11 12 14 SATA...

Page 13: ...16 425 2014 34 SATA GmbH Co KG Domertalstrasse 20 D 70806 Kornwestheim SATA top air 2016 425 2016 425 DIN EN 14594 3A 2014 34 EU PSA BV DIN EN 1127 1 1 DIN EN 80079 36 1 DIN EN ISO 12100 DGUV Test 041...

Page 14: ...163535 Halterung 163543 Beh lter 176420 O Ring 68 x 2 0 bis Juli 2013 199729 O Ring 71 x 2 0 ab Juli 2013 12 Spare parts Art No Description 24505 Safety quick closure coupling 24612 Nipple 24919 O ri...

Page 15: ...s de fermeture 70789 Joint torique 5 x 2 72611 Valve cpl 81158 Module cpl 82917 Tuyau d air respirable cpl 97311 Tuyau d air en PVC 4 x 2 mm 163535 Dispositif 163543 R cipient 176420 Joint torique 68...

Page 16: ...nhalt erw hnte SATA Produkte sind entweder registrierte Marken oder Marken der SATA GmbH Co KG in den USA und oder anderen L ndern SATA SATAjet and or other SATA products referenced herein are either...

Reviews: