-24-
Electrical Adjustments
1. Receive the 16-step grey scale computer signal with
Computer2 [RGB]
mode.
2. Enter the service mode
3. Connect a digital voltmeter to test point “
TPG1
” (+)
and chassis ground (-).
4. Select group no. “
10
”, item no. “
0
” and change data
value to adjust the voltage to be
7.50
±0.05V.
5. Connect a digital voltmeter to test point “
TPR1
” (+)
and chassis ground (-).
6. Select item no. “
1
” and change data value to adjust
the voltage to be
7.50
±0.05V.
7. Connect a digital voltmeter to test point “
TPB1
” (+)
and chassis ground (-).
8. Select item no. “
2
” and change data value to adjust
the voltage to be
7.50
±0.05V.
m
Video Center adjustment
1. Receive the 16-step grey scale composite video sig-
nal with
Video [Video]
mode.
2. Enter the service mode.
3. Connect an oscilloscope to test point “
TPG1
” (+)
and chassis ground (-).
4. Select group no. “
9
”, item no. “
1
” and adjust the ampli-
tude “a” to be minimum by changing the Data value.
5. Connect an oscilloscope to test point “
TPR1
” (+) and
chassis ground (-).
6. Select item no. “
2
” and adjust the amplitude “a” to be
minimum by changing the Data value.
7. Connect an oscilloscope to test point “
TPB1
” (+) and
chassis ground (-).
8. Select item no. “
3
” and adjust the amplitude “a” to be
minimum by changing the Data value.
(a)
White Level
n
Sub Gain adjustment [Video]
1. Receive the 16-step grey scale computer signal with
Computer2 [RGB]
mode.
2. Enter the service mode.
3. Connect an oscilloscope to test point “
TPG1
” (+)
and chassis ground (-).
4. Select group no. “
9
”, item no. “
1
” and adjust the ampli-
tude “a” to be
minimum
by changing the Data value.
5. Connect an oscilloscope to test point “
TPR1
” (+) and
chassis ground (-).
6. Select item no. “
2
” and adjust the amplitude “a” to be
minimum
by changing the Data value.
7. Connect an oscilloscope to test point “
TPB1
” (+) and
chassis ground (-).
8. Select item no. “
3
” and adjust the amplitude “a” to be
minimum
by changing the Data value.
(a)
White Level
b
Sub Gain adjustment [PC]
1. Receive the 16-step gray scale computer signal with
Computer2 [RGB]
mode.
2. Enter the service mode.
3. Connect an oscilloscope to test point “
TPPSIG
” (+)
and chassis ground (-).
4. Select group no. “
10
”, item no. “
14
” and adjust the
amplitude “a” to be
10.0
±0.1V by changing the Data
value.
5. Select item no. “
17
” and adjust the amplitude “b” to be
3.8
±0.1V by changing the Data value.
3. Connect an oscilloscope to test point “
TPZPSIG
” (+)
and chassis ground (-).
4. Select group no. “
10
”, item no. “
12
” and adjust the
amplitude “a” to be
10.0
±0.1V by changing the Data
value.
5. Select item no. “
15
” and adjust the amplitude “b” to be
3.8
±0.1V by changing the Data value.
(a)
(b)
,
PSIG adjustment
Summary of Contents for PLC-XU50
Page 51: ... 51 IC Block Diagrams AD8075 Selector IC201 AN7513 Audio Output IC5601 ...
Page 52: ... 52 BA7078 Sync Separator IC5341 IC Block Diagrams AN5870 RGB SYNC SW IC1201 IC5201 ...
Page 54: ... 54 FA5502 P F Control IC621 IC Block Diagrams CXD3536 LCD Driver IC401 ...
Page 55: ... 55 IC Block Diagrams M62392 M62393 D A IC6271 IC281 ML60851 USB Driver IC9801 ...
Page 56: ... 56 STR Z2156 Power Switching Control IC631 TB1274 Video Decoder IC3101 IC Block Diagrams ...
Page 57: ... 57 IC Block Diagrams TC90A69F Y C Separator IC2101 ...
Page 86: ...MW3 XU5000 MT3 XU5500 86 S5 S5 S5 L9 Projection Mechanical Parts List ...
Page 89: ...MW3 XU5000 MT3 XU5500 89 ...
Page 90: ... MT3A Sep 2003 BB 400 Printed in Japan SANYO Electric Co Ltd ...