− 40 −
1. Never apply voltage to the input terminals.
2. Be sure to make a series connection via load.
(please see to above drawing)
3. Do not apply an input exceeding the maximum rated current
to the input terminals.
5-7 Current Measurement (
A, mA, A)
5-7-1 Current Measurement (
A, mA)
Maximum rating input value DC/AC 4000
A
400mA
1) Applications
Current in DC and AC circuit is measured.
2) Measuring ranges
DCA:400 4000
A, 40 400mA (4 ranges)
ACA:400 4000
A, 40 400mA (4 ranges)
3) Measurement procedure (See Fig 13, page 16)
①
Connect the black plug of the test lead to the COM
input
terminal and the red plug to the
input terminal.
②
Set the function switch at "400 4000
A" or "40 400mA" function.
③
Select the select switch at "
" (DC) or "
" (AC).
④
Apply the black test pin to the negative potential side of the circuit
to measure and the red test pin to the positive potential side.
Fig 6
Power
Power
Load
Load
WARNING
〔×〕
Wrong connection
〔○〕
Right connection
Summary of Contents for PC20
Page 1: ...PC20 DIGITAL MULTIMETER 取扱説明書 INSTRUCTION MANUAL ...
Page 2: ......