SUNWAY
TM
SI
MANUALE
D’USO
68/156
DC Insulation Monitoring
Integrated
DCI Monitoring
Integrated
GFCI Monitoring
Integrated
Grid Monitoring
Integrated
AC Short Circuit Current Protection
Integrated
AC grounding detection
Integrated
DC Surge Protection
Integrated
AC Surge Protection
Integrated
Thermal Protection
Integrated
Anti-island protection monitoring
AFD
Interface
AC Connection
Plug-in connector
DC Connection
MC4
Human Machine Interface
LED+(Bluetooth/Wi-Fi+APP)
Communication Port
RS232(USB)+RS485(RJ45)
Communication Mode
Wi-Fi/GPRS/4G(Optional)
General Data
Topology
Transformerless
Consumption at Night [W]
<0.2
Consumption at Standby [W]
6
Operating Temperature Range
-40
℃
~
+60
℃
[45°C to 60°C with derating]
Cooling Method
Natural Convection
Ambient Humidity
0%
~
100% Non-condensing
Altitude
4000m(>3000m power derating)
Noise [dBA]
<25
Ingress Protection
IP65
Mounting
Rear Panel
Dimensions[H*W*D] [mm]
389*367*143
Weight [kg]
12.2
Standard Warranty [Year]
5(standard)/10/15/20/25(Optional)
Applicable Standard
CQC NB/T 32004,EN62109-1/2,EN61000-6-1/2/3/4,
EN50438,EN50549,C10/C11,IEC62116,IEC61727,RD16
99,
G98,G99,UNE206006,UNE206007-1,CEI0-21,AS/NZS4
777.2