SUNWAY
TM
SI
MANUALE
D’USO
84/156
Figure 5.8 Connect the inverter
5.3.3 SUNWAY
TM
SI-7K/8K-S2AC Side Electrical Connection
①
Screw off the screws at the AC output wire cover and take out the cover.
Penetrate the AC cable of which the insulation layers has been peeled off
through the AC waterproof locking screw hole of the cover. Lock L wire, N
wire and PE wire tightly as per the marked connection positions on the
interface board.
Fig. 5.9 Connecting the cable
②
After fixing the cover at the AC output wire terminal with screws, tighten