04-2017
CAFE RACER
Manual for technical
39 / 56-EN
EN
7.25 Removing the service boiler
- Remove the cup heating plate and the R side
panel as described in the relative paragraphs.
- Disconnect the heating element (2) electrical con-
nection cables (1).
-
nscrew the nut (3) and remove the ground wire
(4).
-
nscrew the nut (5) and disconnect the right steam
tap connection tube (6).
-
nscrew and remove the temperature probe (7).
- Disconnect the maximum level probe connector
(8).
- Disconnect the minimum level probe connector
(9).
- nscrew the nut (10) and disconnect the air bleed
tube (11).
-
nscrew the nut (12) and remove the transducer
tube (13).
-
nscrew the nut (14) and disconnect the left steam
tap connection tube (15).
-
nscrew the nuts (16) and disconnect the mixed
water solenoid valve connection tube (17).
PRELIMINARY REV 00
6
5
3
4
5
1
2
7
8
9
10
11
12
13
14
16
17
16
15