6.4 Resetting the small boiler safety thermostat
- Remove the cup heating plate as described in the
relevant paragraph.
- Press the safety thermostat (1) to reset it.
If the thermostat trips again when
the machine is restarted after re-
setting the safety thermostat,
check the adjustment of the small
boiler temperature thermostat or
its proper functioning.
6.5 Resetting the unit safety thermostat
- Remove the unit guards as described in the rele
-
vant paragraph.
- Press the safety thermostat (1) to reset it.
If the thermostat trips again when
the machine is restarted after re-
setting the safety thermostat,
check the adjustment of the small
boiler temperature thermostat or
its proper functioning.