Operating Manual Q-Jet CT20
© Sanosil
12/32
•
In "Mode selection" chose an operating mode
•
Select "Auto".
•
Define the room size in m
3
•
Select the desired dose per m
3
•
Select the distance from the nozzle to the walls
and ceiling. (If the distance is specified incorrectly,
the disinfectant may be dosed too quickly and can-
not be distributed in the best possible way.)
•
Then go to "Next"
•
Check the specifications
•
Then tap "Start Cycle" to start the
disinfection process
•
Leave the room and wait until the disinfection pro-
gram has finished
4.2.2 Expert mode
Expert mode enables defined, reproducible disinfection results and disinfection cycles that are precisely cus-
tomised for individual rooms. Expert mode thus makes it possible to achieve disinfection results that comply
with the conditions of use set out in DIN EN 17272.
The desired quantity of disinfectant can be distributed manually via up to 4 cycles of a configurable length as
well as 3 customisable intermediate pauses. This enables the best possible disinfection results, but also requires
a certain understanding of aerosol mechanics and how the dosage, cycle and pause length interact depending
on the room to be treated. Otherwise, unwanted condensation may form.