7
the three-phase version, power cables type H07RN-F-5G 2.5 mm² (2.5 m long), power cables for pumps type
H07RN-F-4G1.5 mm² (4 meters in length).
• HF remote alarm unit
• Accessory bag with: 2 chains and 2 stainless steel snap hooks, 5 cable glands (2 x PG13 and 3 x PG11), 2
x IP 68 waterproof terminal blocks: 4 conductors for pumps, 3 terminal blocks IP 68: 2 conductors for floats, 2
sockets Ø100/110/125, 5 hose clamps, 1 pipe seal, cable clips, screws.
A 40 cm height extension is available for the SANIFOS
®
610 and SANIFOS
®
1300 (see pg.10-11).
3.3 Rating plate
1
9
8
7
6
2
3
4
5
1 Name of the pumping station
2 Power consumption of the engines
3 Supply voltage
4 Frequency
5 Protection index
6 Date of production
7 Identification number
8 Max height
9 Max flow rate
3.4 Design and operating mode
The pumping station is equipped with several horizontal inlet openings or drilling zones, for 40/50/100/110/125 mm
external diameter piping (depending on the model).
The motor-pump assembly conveys the pumped fluid in the discharge pipe with an external diameter of 50 mm
(DN 40) in maceration version or external diameter of 63 mm (DN 50) in vortex.
The ventilation duct (external diameter 75 mm, or 100mm on the SANIFOS
®
1300) allows the tank to always
remain at atmospheric pressure (1 ventilation hole on the SANIFOS
®
110 P, SANIFOS
®
280,
SANIFOS
®
610 and
4 ventilation holes on the SANIFOS
®
1300 pumping station).
3.4.1 SANIFOS
®
110 P, SANIFOS
®
280 and SANIFOS
®
610 (single-pump model)
Operating mode:
Effluents enter the pumping station through the horizontal and vertical inlet openings.
They accumulate in a gas-tight, smell-proof and watertight plastic tank.
As soon as a certain fill level is detected by the float switch, the pump starts up automatically.
Effluents are automatically raised up to flow into the drain pipe.
As soon as the effluent level reaches a minimum effluent level in the tank, detected by the float switch, the pump
switches off automatically.
3.4.2 SANIFOS
®
610 (2-pump model) and SANIFOS
®
1300
Operating mode:
Effluents enter the pumping station through the horizontal and vertical inlet openings. They accumulate in a gas-
tight, smell-proof and watertight plastic tank. When the effluent enters the tank, the low float rises and then the high
float rises to reach the pump's activation level.
SANIFOS
®
110 P
SANIFOS
®
280
DISCHARGE
DN 40 (Øext 50) for maceration model
DN 50 (Øext 63) for Vortex model
VENTILATION
Øext 75
INLET (opening to be drilled)
DN 50 or DN 100