17
4.6 Discharge hole
4.7 Water inlet holes
SANIFOS
®
110 P
4 inputs available :
• 2 side inputs Ø ext. 40/50
• 2 side inputs Ø ext. 100/110/125
SANIFOS
®
280 and SANIFOS
®
610 SANIFOS
®
1300
1 side input available : DN 50 or DN100 1 side input available : Ø ext. 160
5. INSTALLATION / ASSEMBLY
• PVC pressure PN10 or 16 (recommended by the manufacturer)
• Flexible "reinforced" type HDPE
NOTE
To prevent the risk of back-flow of water from the sewer, install the discharge pipe in
a "loop" so that its base, at the highest point, is located above the back-flow level.
Improper fitting of the discharge pipe.
Leaks and flooding in the installation
room!
➜
The pumping station must not be used as a
support point for piping.
➜
Do not connect other drain pipes to the discharge
pipe.
➜
Install shut-off valves on thesupply pipes and
discharge pipes (already installed on SANIFOS
®
280, SANIFOS
®
610 and SANIFOS
®
1300).