6.1.3.ACTIVATING BOOST

6.1.3.1.

Definition

The Boost function automatically sets the production setpoints to maximum for a cumulative 

period of 24 hours of filtration time (accounting for filtration stoppages).

6.1.3.2.

Activation/deactivation

Press the  

 button to activate the Boost 

function. The active polarity LED will flash.

 or 

 

Press the  

 button again to deactivate the 

function.

Notes :

•  Once Boost has finished, the setpoint returns to the value configured before Boost was 

activated.

•  The Boost time cannot be adjusted.

Observations: 

•  If the cover/shutter function is used while a Boost is in progress, Boost will be deactivated.
•  The Boost function can only be activated when the cover/shutter function is off.

NEVER MANUALLY COVER THE POOL WHILE BOOST IS IN PROGRESS

•  The Boost function will only activate when the production setpoint is not equal to zero.

6.1.4.REVERSE POLARITY

Your salt water chlorinator comes with a self-cleaning function for the cell. This involves your salt 

water chlorinator periodically changing the polarity of your cell.

In some situations, you may need to alter the reversal time or force the reversal.

6.1.4.1.

Forced reversal

This function enables you to perform 

one reversal.

Press the 

 and 

  buttons to trigger the reversal 

cycle. The green and yellow LEDs will alternately glow 

during the cycle. At the end of the cycle, they will 

stop on green if the start colour was yellow, and vice 

versa.

        

 

 

 ou 

Summary of Contents for SaltLine 040

Page 1: ...NOT210525_SALTLINE_FR_ENG Saltline lectrolyseur lectrolyse au sel Salt water chlorinator ENG p 20 FR p 2 NOTICE MANUAL...

Page 2: ...prot g s contre toute d t rioration accidentelle Un c ble endommag doit tre imm diatement remplac exclusivement par un c ble d origine Ne jamais couper ou rallonger les c bles Couper imp rativement l...

Page 3: ...l lectrolyseur 11 6 1 2 R glage de la puissance de production 11 6 1 3 Activation du mode BOOST 12 6 1 3 1 D finition 12 6 1 3 2 Activation D sactivation 12 6 1 4 Inversion de polarit 12 6 1 4 1 Inver...

Page 4: ...ALLATION AVANT DE PROC DER L INSTALLATION DE L APPAREIL V RIFIEZ QUE Tous les quipements hydrauliques sont en bon tat de fonctionnement et correctement dimensionn s V rifier en particulier le d bit de...

Page 5: ...loin de la piscine afin de respecter les distances r glementaires propres chaque pays Ne pas le couvrir Raccorder le bo tier lectronique de fa on permanente au coffret lectrique de filtration en l as...

Page 6: ...cas de coupure du flux d eau travers la cellule MONTAGE DU CAPTEUR DE D BIT Installer sur la canalisation le T coller en position horizontale en amont et moins de 2 m de la cellule sans vanne entre la...

Page 7: ...de cette fonction TOUS CES BRANCHEMENTS ET MANIPULATIONS DOIVENT TRE R ALIS S PAR UN PROFESSIONNEL 3 5 INSTALLATION POOL TERRE EN OPTION SUIVANT MOD LE Nous recommandons l installation d un POOL TERR...

Page 8: ...Alca ou TAC Ajouter de l acide chlorhydrique TH Taux de calcaire f ppm 10 30 100 300 Ajouter du chlorure de calcium Ajouter du s questrant calcaire Calci oufaire une d carbonatation M taux Cu Fe Mn mg...

Page 9: ...5 20 25 30 35 40 45 50 55 60 Figure 5 Exemple Votre piscine de 40 m3 un taux de sel de 3 5 g l 35kg m3 0 35 vous devez ajouter 40kg de sel pour tre 4 5 g l 45kg m3 0 45 RECOMMANDATION Mettre la quanti...

Page 10: ...vant de votre SALTLINE Reconfigurer votre lectrolyseur si n cessaire en cas d installation suppression du capteur de d bit 6 1 5 4 R gler votre puissance de production 6 1 2 Note Si un renouvellement...

Page 11: ...activer ou d sactiver le mode de pr sence de la couverture 6 1 1 Mise en marche de l lectrolyseur Basculer l interrupteur marche arr t sur la position I 6 1 2 R glage de la puissance de production Un...

Page 12: ...fonction BOOST ne peut pas tre activ e si la fonction Couverture volet est d j active NE JAMAIS COUVRIR LE BASSIN MANUELLEMENT ALORS QUE LA FONCTION BOOST EST EN COURS La fonction BOOST ne s activera...

Page 13: ...n programmer le temps souhait Cf Figure 10 12h00 8h00 4h00 24h00 Inter 2 ON OFF ON OFF Inter 1 ON ON OFF OFF Figure 10 6 1 5 Fonction couverture ou volet 6 1 5 1 Objectif Si vous utilisez un syst me d...

Page 14: ...le mode automatique est actif Si la fonction couverture volet avait t activ e avant l activation du mode automatique elle sera automatiquement d sactiv e quand le volet sera en position ouvert 6 1 5 3...

Page 15: ...r glage production soit au maximum Cf 6 1 2 Le disjoncteur du coffret de commande de la pompe disjoncte Tenir compte de la consommation lectrique de l lectrolyseur ajouter 1A au r glage du disjoncteur...

Page 16: ...afin d isoler le circuit D monter la cellule ou l lectrode Fermer un c t de la cellule avec un bouchon Positionner la cellule la verticale Positionner l lectrode dans un r cipient qui permet de recou...

Page 17: ...ics annule toute garantie 9 3 S A V Toutes les r parations s effectuent dans nos ateliers Les frais de transport aller et retour sont la charge de l utilisateur L immobilisation et la privation de jou...

Page 18: ...r utilisables et recyclables Toutefois les diff rentes parties qui les composent ne sont pas biod gradables Les directives environnementales europ ennes D E E E r glementent la fin de vie des quipeme...

Page 19: ...ced exclusively by an original cable Never cut or extend cables The power supply must be turned off before any technical intervention on the appliance Do not modify the appliance Any modification may...

Page 20: ...ANEL 27 6 1 1 Starting the salt water chlorinator 28 6 1 2 ADJUSTING THE PRODUCTION LEVEL 28 6 1 3 ACTIVATING BOOST 29 6 1 3 1 Definition 29 6 1 3 2 Activation deactivation 29 6 1 4 REVERSE POLARITY 2...

Page 21: ...ground electrode inch saddle clamp 3 INSTALLATION BEFORE INSTALLING THE APPLIANCE CHECK THAT All hydraulic equipment is in good working order and properly sized Check the filtration pump flow filter c...

Page 22: ...th your country s regulations Do not cover it Permanently connect the electronic control unit to the filtration unit s electrical cabinet by slaving it to the pump contactor Do not use an extension co...

Page 23: ...r not flowing through the cell SETTING UP THE FLOW SENSOR Install the tee glue on in a horizontal position on the pipe upstream and at least 2 metres from the cell with no valve between the cell and s...

Page 24: ...for how to use this function ALL CONNECTIONS AND PROCEDURES MUST BE PERFORMED BY A PROFESSIONAL 3 5 INSTALLING THE GROUND ELECTRODE optional extra depending on model We recommend installing a ground...

Page 25: ...Add hydrochloric acid TH Calcium Hardness f ppm 10 30 100 300 Add calcium chloride Add a calcium sequestrant Calci or perform a decarbonation process Metals Cu Fe Mn etc mg L ou ppm 0 Add metal seque...

Page 26: ...15 20 25 30 35 40 45 50 55 60 Figure 5 For example If your 40 m pool has a salt level of 3 5 g l 35 kg m 0 35 you must add 40 kg of salt to reach 4 5 g l 45 kg m 0 45 RECOMMENDATION Add the salt in on...

Page 27: ...gs on your salt water chlorinator if required when installing or removing the flow sensor Section 6 1 5 4 Adjust your production level Section 6 1 2 Note If you have refilled the pool or added a signi...

Page 28: ...the Boost mode COVER For activating and deactivating the cover on mode 6 1 1 Starting the salt water chlorinator Flip the on off switch to the l position 6 1 2 ADJUSTING THE PRODUCTION LEVEL Press th...

Page 29: ...ll be deactivated The Boost function can only be activated when the cover shutter function is off NEVER MANUALLY COVER THE POOL WHILE BOOST IS IN PROGRESS The Boost function will only activate when th...

Page 30: ...the desired time see Figure 10 below 12h00 8h00 4h00 24h00 Inter 2 ON OFF ON OFF Inter 1 ON ON OFF OFF Figure 10 6 1 5 COVER OR SHUTTER FUNCTION 6 1 5 1 Objective If you use a pool cover system follow...

Page 31: ...button is disabled when the automatic mode is on If the cover shutter function has been activated before the automatic mode activates it will automatically be deactivated when the shutter opens 6 1 5...

Page 32: ...level is a bit low Check that the production setting is on maximum See Section 6 1 2 The pump control panel s circuit breaker trips Look at the salt water chlorinator s electricity consumption add 1A...

Page 33: ...or electrode Close one end of the cell with a plug Bring the cell to a vertical position Put the electrode in a container that big enough for the entire active part to be covered Fill the cell or cont...

Page 34: ...RATION APPLICABLE FROM THE INVOICE DATE Electronic control unit 2 years 24 months Electrolysis cell 2 years 24 months Repairs and spare parts 3 months 9 2 PURPOSE OF THE WARRANTY The warranty applies...

Page 35: ...f the warranty 9 5 IMPLEMENTATION OF THE WARRANTY Call your professional for more information on the current warranty Any request will have to be accompanied by a copy of the purchase invoice 9 6 LAWS...

Page 36: ...RRANTY CERTIFICATE Keep this attached certificate and the receipt The serial number mentioned on this page will be required for any claim IMPORTANT Read and carefully follow the assembly and operating...