21
1.TECHNICAL SPECIFICATIONS
Dimensions (HxWxD)
380 mm x 270 mm x 110 mm
Weight
7 kg
Power supply
230v AC +/-10% 50Hz
Models
040
060
090
140
Power consumption by model
40 W
95 W
145 W
200 W
Min./max. flow in cell
100 l/h -450 : l/h
Operating temperature
0°C
45°C
Protection
IP X2
2.BOX CONTENTS
• 1 electronic control unit
• 1 wall-mount kit
• 1 cell and kit with hydraulic connectors according to cell model
OPTIONAL EXTRA OR ACCORDING TO VERSION:
• 1 flow sensor and ¾” (glue-on) tee or saddle clamp
• 1 ground ele ½-inch saddle clamp
3.INSTALLATION
BEFORE INSTALLING THE APPLIANCE, CHECK THAT:
• All hydraulic equipment is in good working order and properly sized. Check the filtration pump
flow, filter capacity and pipe diameter in particular.
• The pump room is dry and properly ventilated, and protected from the rain, splashes, water
spray and UV rays (maximum ambient temperature for use: 45°C).
• When a pH adjuster is used, the pH adjuster product’s container must be at a sufficient
distance from all electrical devices and all other chemical products.
Failure to follow
this instruction will lead to the abnormal oxidation of metal parts that may result in the
appliance’s complete failure.