(h)  Never place a switch where it can be reached from a tub or shower.

(i)  CAUTION: For General Ventilating Use Only. Do Not Use To Exhaust Hazardous Or 

Explosive Materials And Vapors.

(j)  CAUTION:  MOUNT WITH THE LOWEST MOVING PARTS AT LEAST 2.4 M (8 FEET) 

ABOVE THE FLOOR OR GRADE LEVEL.

(k) All units are suitable for use with solid-state speed control.

The TD - MIXVENT series can be mounted in any orientation, horizontal or vertical, and is suitable 

for numerous types of applications. See 

Figure (1)

. Illustration of some typical applications.

If  the  installation  is  made  to  rigid  or  flexible  ducting,  then  we  would  recommend  the  correct 

diameter ducting is used to couple to the fan flanges. If it is necessary to bend the duct at the 

discharge of the fan, then the bend radius should be as large as possible. When rigid duct is 

used, make sure to use round elbows.

Before installing the product check the following points: (1) the fan impeller turns freely and (2) 

there are no obstructions to the airflow.

All models include a robust mounting bracket which enables easy and quick installation of the fan. 

See

 Figure (2) 

Installation Diagrams For TD - MIXVENT Duct Fans.

Ductwork connection should be made with duct tape or duct fast-clamps (available through your 

local distributor) to ensure a good seal and secure connection.

Ensure duct joints and exterior penetrations are sealed with caulk or other similar material to 

create an air-tight path and to minimize building heat loss and gain and reduce the potential for 

condensation.

Place/wrap  insulation  around  duct  and/or  fan  to  in  order  to  minimize  possible  condensation 

buildup within the duct, building heat loss and gain.

Duct

Tape

Tape

Duct

Fan

To ensure quiet operation of ENERGY STAR qualified inline 

and  remote  fans,  each  fan  shall  be  installed  using  sound 

attenuation  techniques  appropriate  for  the  installation.  For 

bathroom and general ventilation applications, at least 8 feet of 

insulated flexible duct shall be installed between the exhaust 

or supply grille(s) and the fan. For remote ventilation applications, where metal duct is generally 

required by code, a metal sound attenuator shall be installed between the hood and the fan.

 

ELECTRICAL CONNECTION

All TD - MIXVENT series fans operate from a standard 120V 60Hz AC electrical supply. All wiring 

must be carried out in accordance with National Electrical Code and all applicable state and local 

buildings codes. 

Electrical connections should be made in accordance with the following diagrams:

 Figure (3) 

Electrical Wiring.

 

 

 

 

Model

Recommended 

Round Duct Size (in.)

TD-100

4”

TD-100X1

4”

TD-125

5”

TD-150

6”

TD-200

8”

TD-250

10”

TD-315

12”

Summary of Contents for MIXVENT TD Series

Page 1: ...ENTRIFUGES EN LIGNE Models TD 100 TD 100X1 TD 125 TD 150 TD 200 TD 250 TD 315 INSTALLATION AND WIRING INSTRUCTIONS INSTRUCCIONES DE MONTAJE INSTRUCTIONS DE MONTAGE English Espa ol Fran ais READ AND SA...

Page 2: ...o install the TD MIXVENT models the fan motor wheel assembly must first be removed Loosen the two spring clips around the casing and remove Desmontar el cuerpo motor aflojando los tornillos de las dos...

Page 3: ...gu lateur de vitesse TD 250 315 TD 250 315 TD 100 100X1 125 150 200 TD 100 100X1 125 150 200 IMPORTANT LES TD 250 315 INCORPORENT UN MOTEUR 120V 60Hz A DEUX VITESSES LA PHASE DOIT TRE RACCORDEE SOIT A...

Page 4: ...only in the manner intended by the manufacturer If you have any questions contact the manufacturer b Before servicing or cleaning the unit switch the power off at the service panel and lock the servic...

Page 5: ...fast clamps available through your local distributor to ensure a good seal and secure connection Ensure duct joints and exterior penetrations are sealed with caulk or other similar material to create...

Page 6: ...Bath Kits have an extended warranty period of 7 years from the date of original purchase IF CLAIMING UNDER WARRANTY Please return the complete product freight paid to you local authorized distributor...

Page 7: ...modelos TD 100 125 y 200 y de 40 C hasta 60 C para los modelos TD 150 y 250 315 INSTALACI N ATENCI N PARA REDUCIR EL RIESGO DE INCENDIO DE DESCARGA EL CTRICA O DA OS A PERSONAS OBSERVAR LO SIGUIENTE...

Page 8: ...ntaje de los ventiladores TD MIXVENT La conexi n de los conductos debe hacerse con banda adhesiva o bridas de sujeci n disponibles en su almacenista local para asegurar una conexi n segura y estanca C...

Page 9: ...es o como resultado de una utilizaci n incorrecta como Mantenimiento incorrecto Mal uso Manipulaci n Incorrecta Accidente en el suministro de corriente tensi n o corriente incorrecta Si se quita o alt...

Page 10: ...0 y 250 315 INSTALLATION ATTENTION POUR MINIMISER LE RISQUE D INCENDIE DE CHOC LECTRIQUE OU DE BLESSURES AUX PERSONNES PRIERE D OBSERVER LES REGLES SUIVANTES a Utilisez cet appareil uniquement tel que...

Page 11: ...rbine du ventilateur tourne librement et 2 qu il n y a pas d obstruction l cou lement de l air Tous les mod les incorporent un support robuste qui permet un montage facile et rapide du ventilateur Voi...

Page 12: ...GARANTIE N EST PAS APPLICABLE Aux dommages de transport cach s ou visibles La r clamation doit tre pr sent e au transporteur Aux dommages dus des catastrophes naturelles ou r sultant d une mauvaise u...

Reviews: