Figure 3.

 Electrical Wiring / Conexión Eléctrica / Branchement Electrique:

TD - MIXVENT FLOW.

• Motor without Speed Controller / Motor sin regulador de velocidad / Moteur sans 

régulateur de vitesse.

 

IMPORTANT:

 Models  TD-100 through to TD-200 are double insulated and  

 

are not provided with external ground wire

• Motor with Speed Controller / Motor con regulador de velocidad/Moteur avec régu-

lateur de vitesse.

TD 250 & 315

TD 250 & 315

TD 100, 100X1, 125 & 150, 200

TD-100, 100X1, 125, 150 & 200

IMPORTANT

LES TD-250 & 315 INCORPORENT

UN MOTEUR (120V 60Hz) A DEUX VITESSES. LA PHASE DOIT

ÊTRE RACCORDEE SOIT AU TERMINAL 

HI

 SOIT AU TERMINAL

 LO

– MAIS PAS AUX DEUX A LA FOIS -

IMPORTANT

THE TD-250 & 315 MODELS INCORPORATE TWO SPEED

(120VAC 60Hz) MOTORS. THE LIVE SUPPLY MUST ONLY

BE MADE TO TERMINAL 

HI

 OR

 LO

 CONNECTION - NOT TOGETHER-

IMPORTANTE

LOS TD-250 &315 INCORPORAN

UN MOTOR (120V 60Hz) DE DOS VELOCIDADES. LA FASE TIENE

QUE CONECTARSE ÚNICAMENTE AL TERMINAL 

HI 

LO

– NO A LOS DOS A LA VEZ -

Summary of Contents for MIXVENT TD Series

Page 1: ...ENTRIFUGES EN LIGNE Models TD 100 TD 100X1 TD 125 TD 150 TD 200 TD 250 TD 315 INSTALLATION AND WIRING INSTRUCTIONS INSTRUCCIONES DE MONTAJE INSTRUCTIONS DE MONTAGE English Espa ol Fran ais READ AND SA...

Page 2: ...o install the TD MIXVENT models the fan motor wheel assembly must first be removed Loosen the two spring clips around the casing and remove Desmontar el cuerpo motor aflojando los tornillos de las dos...

Page 3: ...gu lateur de vitesse TD 250 315 TD 250 315 TD 100 100X1 125 150 200 TD 100 100X1 125 150 200 IMPORTANT LES TD 250 315 INCORPORENT UN MOTEUR 120V 60Hz A DEUX VITESSES LA PHASE DOIT TRE RACCORDEE SOIT A...

Page 4: ...only in the manner intended by the manufacturer If you have any questions contact the manufacturer b Before servicing or cleaning the unit switch the power off at the service panel and lock the servic...

Page 5: ...fast clamps available through your local distributor to ensure a good seal and secure connection Ensure duct joints and exterior penetrations are sealed with caulk or other similar material to create...

Page 6: ...Bath Kits have an extended warranty period of 7 years from the date of original purchase IF CLAIMING UNDER WARRANTY Please return the complete product freight paid to you local authorized distributor...

Page 7: ...modelos TD 100 125 y 200 y de 40 C hasta 60 C para los modelos TD 150 y 250 315 INSTALACI N ATENCI N PARA REDUCIR EL RIESGO DE INCENDIO DE DESCARGA EL CTRICA O DA OS A PERSONAS OBSERVAR LO SIGUIENTE...

Page 8: ...ntaje de los ventiladores TD MIXVENT La conexi n de los conductos debe hacerse con banda adhesiva o bridas de sujeci n disponibles en su almacenista local para asegurar una conexi n segura y estanca C...

Page 9: ...es o como resultado de una utilizaci n incorrecta como Mantenimiento incorrecto Mal uso Manipulaci n Incorrecta Accidente en el suministro de corriente tensi n o corriente incorrecta Si se quita o alt...

Page 10: ...0 y 250 315 INSTALLATION ATTENTION POUR MINIMISER LE RISQUE D INCENDIE DE CHOC LECTRIQUE OU DE BLESSURES AUX PERSONNES PRIERE D OBSERVER LES REGLES SUIVANTES a Utilisez cet appareil uniquement tel que...

Page 11: ...rbine du ventilateur tourne librement et 2 qu il n y a pas d obstruction l cou lement de l air Tous les mod les incorporent un support robuste qui permet un montage facile et rapide du ventilateur Voi...

Page 12: ...GARANTIE N EST PAS APPLICABLE Aux dommages de transport cach s ou visibles La r clamation doit tre pr sent e au transporteur Aux dommages dus des catastrophes naturelles ou r sultant d une mauvaise u...

Reviews: