TD - MIXVENT SERIES

The TD - MIXVENT mixed flow range of in-line duct exhaust fans have been manufactured in 

accordance  with  the  rigorous  standards  of  production  as  defined  by  the  International  Quality 

Standards ISO 9001. All the components have been checked and tested at the end of the 

manufacturing process.

We recommend that you check the following after receiving this product:

1. The correct size has been received

2. The correct model has been received

3. The details on the rating label correspond to the electrical supply: voltage, frequency 

etc.

Remove the unit from packaging and inspect for shipping damage within 15 days of receipt. If 

the product is found to be damaged, immediately contact your local authorized supplier. DO NOT 

OPERATE THE UNIT IF DAMAGED.

These instructions should be considered as a supplement to EPA standard practices, as well as 

all state and local building code regulations.

ENVIRONMENT

The TD-Mixvent series of fans are suitable for operation within indoor environments only, 

except the TD-250 and 315x which are UL approved for outdoor use. The TD-Mixvent units are 

suitable for the exhaust or supply of both conditioned and un-conditioned airstreams within the 

temperature ranges. Sizes 100-125, & 200 are suitable for working airstreams up to 104 deg F 

(40C), whereas sizes 150, & 250-315 are suitable for working airstreams up to 140 deg F (60C).

INSTALLATION

WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, OR INJURY TO 

PERSONS, OBSERVE THE FOLLOWING:

(a) Use this unit only in the manner intended by the manufacturer. If you have any 

questions contact the manufacturer.

(b)  Before servicing or cleaning the unit, switch the power off at the service panel and lock 

the service disconnecting means to prevent power from being switched on accidentally. 

When the service disconnecting means cannot be locked; securely fasten a prominent 

warning device such as a tag to the service panel.

(c)  Installation work and electrical wiring must be done by qualified person(s) in accordance 

with all applicable codes & standards including fire rated construction.

(d)  Sufficient air is needed for proper combustion and exhausting of gases through the 

flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating 

equipment manufacturers guideline and safety standards such as those published by 

the National Fire Protection Association (NFPA) and the American Society For Heating, 

Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

(e)  When cutting or drilling into wall or ceiling, do not damage electrical wiring and other 

hidden utilities.

(f)  The  ducting  from  this  fan  to  the  outside  of  the  building  has  a  strong  effect  on  the 

air flow, noise and energy use of the fan. Use the shortest, straightest duct routing 

possible for best performance, and avoid installing the fan with smaller ducts than 

recommended. Insulation around the ducts can reduce energy loss and inhibit mold 

growth. Fans installed with existing ducts may not achieve their rated airflow.

(g)  If this unit is to be installed over a tub or a shower, it must be marked as appropriate for 

the application and connected to a GFCI (Ground Fault Circuit Interrupter) - protected 

branch circuit.

Summary of Contents for MIXVENT TD Series

Page 1: ...ENTRIFUGES EN LIGNE Models TD 100 TD 100X1 TD 125 TD 150 TD 200 TD 250 TD 315 INSTALLATION AND WIRING INSTRUCTIONS INSTRUCCIONES DE MONTAJE INSTRUCTIONS DE MONTAGE English Espa ol Fran ais READ AND SA...

Page 2: ...o install the TD MIXVENT models the fan motor wheel assembly must first be removed Loosen the two spring clips around the casing and remove Desmontar el cuerpo motor aflojando los tornillos de las dos...

Page 3: ...gu lateur de vitesse TD 250 315 TD 250 315 TD 100 100X1 125 150 200 TD 100 100X1 125 150 200 IMPORTANT LES TD 250 315 INCORPORENT UN MOTEUR 120V 60Hz A DEUX VITESSES LA PHASE DOIT TRE RACCORDEE SOIT A...

Page 4: ...only in the manner intended by the manufacturer If you have any questions contact the manufacturer b Before servicing or cleaning the unit switch the power off at the service panel and lock the servic...

Page 5: ...fast clamps available through your local distributor to ensure a good seal and secure connection Ensure duct joints and exterior penetrations are sealed with caulk or other similar material to create...

Page 6: ...Bath Kits have an extended warranty period of 7 years from the date of original purchase IF CLAIMING UNDER WARRANTY Please return the complete product freight paid to you local authorized distributor...

Page 7: ...modelos TD 100 125 y 200 y de 40 C hasta 60 C para los modelos TD 150 y 250 315 INSTALACI N ATENCI N PARA REDUCIR EL RIESGO DE INCENDIO DE DESCARGA EL CTRICA O DA OS A PERSONAS OBSERVAR LO SIGUIENTE...

Page 8: ...ntaje de los ventiladores TD MIXVENT La conexi n de los conductos debe hacerse con banda adhesiva o bridas de sujeci n disponibles en su almacenista local para asegurar una conexi n segura y estanca C...

Page 9: ...es o como resultado de una utilizaci n incorrecta como Mantenimiento incorrecto Mal uso Manipulaci n Incorrecta Accidente en el suministro de corriente tensi n o corriente incorrecta Si se quita o alt...

Page 10: ...0 y 250 315 INSTALLATION ATTENTION POUR MINIMISER LE RISQUE D INCENDIE DE CHOC LECTRIQUE OU DE BLESSURES AUX PERSONNES PRIERE D OBSERVER LES REGLES SUIVANTES a Utilisez cet appareil uniquement tel que...

Page 11: ...rbine du ventilateur tourne librement et 2 qu il n y a pas d obstruction l cou lement de l air Tous les mod les incorporent un support robuste qui permet un montage facile et rapide du ventilateur Voi...

Page 12: ...GARANTIE N EST PAS APPLICABLE Aux dommages de transport cach s ou visibles La r clamation doit tre pr sent e au transporteur Aux dommages dus des catastrophes naturelles ou r sultant d une mauvaise u...

Reviews: