6.8 Page 8: RADALT
The Radalt page selects the configuration of Radar altimeter input. If no Radar altimeter is
installed set configuration of RALT to NONE.
Radar altimeters are selected by equipment type, i.e. ALT55 for Collins ALT55 altimeter, etc.
Once the equipment is selected, the Radar altitude can be read from the data VALUE line to
check for correct operation.
For analog inputs, a corresponding VALID input is present. Ensure that this item is VALID
during normal operation and INVALID during TEST of the RA or when the RA is powered
off.