Ground Bonding.
Bonding of the ST3400H shall be in accordance with AC 43.13-1B,
Chapter 11, Section 15. After installation, bonding shall be measured and the result shall be 10
milliohms or less between the ST3400H case and the instrument panel.
Power Wiring
. To assure that the ST3400H will operate properly down to its rated minimum
input voltage, ensure that two power wires of at least the recommended size are connected in
accordance with the installation drawings.