It is a screen for general additional functions and additional setting in stationary operation.
04. Operation motion setting
4-1. Operation method setting
● It converts to the “Setting screen for operation related motion” when the operation motion setting is selected in [Fig. 2-1 Main screen]
[Fig. 4-1] Setting screen for operation related motion
2
3
4
5
1
6
7
①
②
③
Setting with selection either of pattern or stationary operation
for operation mode.(It cannot be changed during operation.)
●
Pattern : Setting in program operation
●
Stationary : Setting in stationary operation
Setting the recovery motion in black out
●
Stop : A motion to return to the operation stop state after
power on from the black out.
●
Re-start : An operation from the beginning after power on from
the black out.
●
Continue : A motion to return to the previous operation state
after power on from the black out.
In case that the external disturbances occure, stabilized the control.
●
No operation : The indicated value is stabilized depending on time
when the overshoot is made.
●
Operation : The indicated value is stabilized faster than No operation
case, as the overshoot controlling function is provided.
Automatic increase or decreased with the set rate in case of set value change
●
It is adopted in stationary operation only.
Total operation in set time and in [3-1(4) Stationary operation #2 operation screen
The operation stops when the process time is coincided with the set time.
●
It is adopted in stationary operation only.
④
⑤
04. Operation motion setting