background image

References

 It is a screen in case of DI error creation.

 The setting for letter and photo screen setting can be set in [11. DI function and operation setting] in [Installation manual]. 

 It is converted to the operation screen after escaping from the DI error screen when             is touched by.

 The same DI error creation is neglected for 1 minute when the screen is changed by pressing             button after DI creation. (Here, the neglecting means the DI error screen.)

  Ex) It neglects even DI1 is created by escaping with “Return” in the stat of DI1 creation and the DI error screen is displayed when DI1 has been created even after 1 minute. 

              button is to block the alarming sound when DI error is created.

  EX) Explanation depending on lamp state
  - DI error no creation (“OFF” state)
  - DI error creation (“ON” state)
  - Release after DI error creation (“ON” state after “OFF” )

72

[Fig. 8-4] Screen for DI error display method by letter

[Fig. 8-5] Screen for DI error display method by photo

Summary of Contents for TEMI1000 Series

Page 1: ......

Page 2: ...thout prior written consent of Samwontech Co Ltd Please inform the TEMI1000 model name failure condition and contact point for queries of after sales service Queries related with after sales service f...

Page 3: ...Appointed operation setting 36 6 Setting graph display and save 6 1 Pattern graph display 41 6 2 Presented value PV graph view 44 6 3 Presented value PV graph save setting 47 6 4 Memory save setting 4...

Page 4: ...tion and safety for this product and the system connected to this system The internal modification Change and addition to this product are prohibited Do not disassemble repair and modify of this produ...

Page 5: ...Operation and setting 1 1 Basic operation flow chart 4 1 2 Setting button operation 5 1 3 Setting button operation 6 Part 01...

Page 6: ...allation of the product and it converts to the program stationary screen It takes about 20 seconds for screen loading When button is touched at the top of the program stationary screen it converts to...

Page 7: ...d by the user It is used for inputting the general numbers and name It is used for selection for one out of many types It is used for selection for one out of more than 2 parameter setting ON OFF Inac...

Page 8: ...is selected in 1 2 Setting button operation the input key of the setting value is shown as followings and the necessary data can be input When the data out of the setting range is input error message...

Page 9: ...key is out of the input range Do not press with sharp thing Pencil and etc or excessive force on the input key for basic setting button or setting value It may cause the mal operation of the device or...

Page 10: ...Part 02 Main screen 9...

Page 11: ...urrent time programmed operation time Moving to the screen to set Y N for using graph display graph record Moving to the program setting menu screen Moving to the screen for setting the screen brightn...

Page 12: ...esent temperature value PV It displays the present humidity value PV Button to move the operation screen During operation the button is displayed alternately in various colors References PV on the lef...

Page 13: ...Operation state screen setting 3 1 Stationary operation 13 3 2 Program operation 20 3 3 Auto tuning and tuning point 29 Part 03...

Page 14: ...3 1 Stationary operation still screen 1 Fig 3 5 Stationary operation still screen 1 Fig 3 9 Stationary operation still screen 2 Fig 3 10 Stationary operation still screen 3 Operation state screen sett...

Page 15: ...1 Select the operation method with Stationary in 4 Operation motion setting When at the right bottom of Fig 3 1 Stationary operation still screen 1 is touched by it converts to Fig 3 5 Stationary oper...

Page 16: ...e setting about operation temperature The input for set value for humidity is activated when button is touched Fig 3 4 Screen of Input for humidity setting about operation When the input of set data o...

Page 17: ...o be controlled It displays the current date time and LCD backlight is off when it is touched Red LED lamp at the right top is ON when the backlight is OFF in still state Moving to Fig 2 1 Main screen...

Page 18: ...Fig 3 7 Stationary operation operation screen 1 Fig 3 6 Stationary operation still screen 1 16 3 Stationary operation screen 1 TEMI1300 1900 WIDE...

Page 19: ...g the state lamp in 12 System initial setting in Installation manual Setting up to 24 for lamp in 12 System initial setting It displays the control output volume MV in temperature It displays the cont...

Page 20: ...button The saved data into the internal memory are preserved when the electric power is ON OFF Refer to 6 2 Present value PV graph view It displays the measuring data setting data of currently operate...

Page 21: ...by the elapse of setting time in 4 Operation motion setting The message is not appeared on the screen when it is forcibly terminated by pressing Stop button during operation The message is disappeare...

Page 22: ...m operation still screen 1 when the operation state screen is selected in Fig 2 1 Main screen Select the operation method with Pattern in 4 Operation motion setting Refer to 7 1 Program pattern settin...

Page 23: ...r pattern number setting input key to be operated Execute the program by selecting button when the input for the pattern number setting to be operated is completed 03 Operation state screen setting Pa...

Page 24: ...klight is off when it is touched Red LED lamp at the right top is ON when the backlight is OFF in still state Moving to Fig 2 1 Main screen It displays the key pad to input the password when main butt...

Page 25: ...Fig 3 17 Program operation still screen 1 Fig 3 18 Program operation operation screen 1 23 3 Program operation screen 1 TEMI1300 1900 WIDE 03 Operation state screen setting...

Page 26: ...displays the currently operated program pattern number and segment number It displays the pattern repetition state The figure in the front in shows the frequency of repetition and the figure at the en...

Page 27: ...o the internal memory are preserved when the electric power is ON OFF Refer to 6 2 Present value PV graph view 2 3 1 Fig 3 22 Program operation 3 operation screen User Key It displays the measuring da...

Page 28: ...d into the pattern is terminated The message is not appeared on the screen when it is forcibly terminated by pressing Stop button during operation The message is disappeared by touching the correspond...

Page 29: ...e saved PV file Fig 3 25 Screen for warning of shortage of memory capacity References References It is a sending screen for saved PV file in internal memory to PC It takes about 23 second to sending 0...

Page 30: ...saved file number Fig 3 28 warning screen for full of saved file number References Screen for no extra space in intenal memory References Fig 3 27 is a screen when the number of saved files is over 24...

Page 31: ...00 150 00 Set value SP 50 0 Output lower limit OL 0 0 Output upper limit OH 100 0 Auto tuning point 50 2 49 8 49 8 Under tuning PD control Measuring data PV ON ON ON OFF OFF SP 50 0 OH Control output...

Page 32: ...Part 04 Operation motion setting 4 1 Operation method setting 31 4 2 Fuzzy operation 33 4 3 Setting value change rate SLOPE operation 34...

Page 33: ...state after power on from the black out Re start An operation from the beginning after power on from the black out Continue A motion to return to the previous operation state after power on from the...

Page 34: ...EY LOCK Temp change rate Humi change rate Time setting operation Hour Minute Pattern stationary Stop re start continue No operation Operation OFF ON T EUS 0 00 100 00 MIN H EUS 0 0 100 0 MIN No use Us...

Page 35: ...overshoot by calculating the control output value MV with sub target value Super SP instead of present value PV from the overshoot control start time Set value SP Now present value NPV Time Now presen...

Page 36: ...0 0 30 0 TSP PV SP change SP 2minutes 40 0 Change rate Slope operation References Operation method Stationary operation Temperature change rate 20 0 Min Change Changed SP TSP PV at the SP changing poi...

Page 37: ...Part 05 Appointed operation setting 36...

Page 38: ...ointed time when is touched by The appointed time is displayed on the operation screen as shown in Fig 5 2 Operation appointed setting screen when is touched by 2 3 1 36 05 Appointed operation setting...

Page 39: ...37 Fig 5 2 Operation appointed setting screen Program operation Fig 5 3 Operation appointed setting screen Stationary operation 05 Appointed operation setting...

Page 40: ...M Hour Minute Setting range Unit 2000 2009 1 12 1 31 AM PM 1 12 0 59 2000 2009 1 12 1 31 AM PM 1 12 0 59 ABS ABS ABS ABS ABS ABS ABS ABS ABS ABS ABS ABS 2014 1 1 AM 12 0 Current time Appointed operati...

Page 41: ...Part 06 Setting graph display and save 6 1 Pattern graph display 41 6 2 Presented value PV graph view 44 6 3 Presented value PV graph save setting 47 6 4 Memory save setting 48...

Page 42: ...g 6 2 Graph Saving screen 1 Pattern graph display Fig 6 5 Graph Saving screen 2 Graph display selection Fig 6 9 Graph Saving screen 3 Flow chart Setting graph display and save Fig 6 10 Graph Save sett...

Page 43: ...me in program operation It is a screen to display the input pattern in Fig 7 2 Pattern editing screen Can change the status of Temperature Humidity Check and even in the graph screen 41 06 Setting gra...

Page 44: ...n No to be displayed Display the input key to set the pattern No when is touched Refer to Fig 6 4 Pattern No input screen Setting the time on graph X axis Display of the input key to set the time on X...

Page 45: ...1 120 30 minutes 1 hour 3 hours 6 hours 12 hours 24 hours ABS ABS 1 30 minutes Fig 6 4 Pattern No input screen References It is a screen to input the pattern No to be displayed in graph The pattern No...

Page 46: ...and Fig 6 6 Graph Save setting screen 2 Display to update the graph screen immediately which is being saved Moving from current screen to next screen Base line to disply the data checkpoint Using the...

Page 47: ...om the temperature Set Data Indicated Data and humidity Set Data Indicated Data It is a screen to display the saved file into the internal memory Refer to 3 1 5 Stationary operation 3 operation screen...

Page 48: ...impossible when there is not SD card option or during saving the PV graph in operation screen When is touched the files saved into the internal memory is displayed The currently opened folder or file...

Page 49: ...ally Manual Saving the data by the saving key in the Operation screen 3 manually The saved data into the internal meemory are preserved when the electric power is ON OFF Setting the display range of T...

Page 50: ...s out of the saved data in TEMI1000 to SD card It displays the current capacity of SD card It displays when the SD card is inserted only When the data is not in recording to SD card is activated and d...

Page 51: ...Part 07 Program setting 7 1 Program pattern setting 52 7 2 Pattern repetition setting 57 7 3 File editing 58 7 4 Time signal operation 61 7 5 Standby operation 64 7 6 Experiment name setting 66...

Page 52: ...Fig 7 2 Pattern editing screen Fig 7 7 Time signal setting 1 Fig 7 3 Pattern and segment repetition setting screen Fig 7 10 Standby operation setting screen Fig 7 4 File editing screen Fig 7 11 Exper...

Page 53: ...n for setting pattern copy and deletion Moving to the screen for time signal setting Moving to the screen for setting the standby screen Moving to the screen for experiment name It converts to Fig 7 1...

Page 54: ...P1 in segment SEG1 TEMP SSP In case of starting the program operation the present set value SP is started from temperature SSP and progresses to the set time TM1 for currently set value 1 SP1 in segme...

Page 55: ...tton are activated and the selected segment can be inserted when is touched by When one of the buttons Segment 01 99 is touched by for segment deletion the selected button Segment 01 99 and button are...

Page 56: ...n the Pattern number button is touched by When the Starting condition button is touched by the input key to set the starting condition is displayed It is a screen set with TEMP SSP for starting condit...

Page 57: ...ut key to set the set value is displayed when HUMI button is touched by The input key to set the segment time is displayed when Time button is touched by The input key to set the set value is displaye...

Page 58: ...ime signal is displayed when Time signal button is touched by n 1 99 Pattern number Starting condition Segment n TEMP SP Segment n HUMI SP Segment n Time Segment n Time signal 1 4 Segment n Wait use 1...

Page 59: ...et patterns It displays the experiment name of the set pattern The change of the experiment name can be changed in 7 6 Experiment name setting The change is impossible as it is only for reading It dec...

Page 60: ...rst pattern is copied only when the last pattern is 0 It deletes the first and last pattern number to be copied The first pattern is deleted only when the last pattern is 0 It displays the total patte...

Page 61: ...ottom of screen for copying or deleting by wrong input of pattern number References The message There is no saved contents on the selected pattern Appears at the bottom of screen for copying or deleti...

Page 62: ...completed in the selected pattern The deletion is completed in the selected pattern The copy is completed in every pattern The pattern to be copies is being used Explanation It is displayed in case of...

Page 63: ...g the time signal No in segment setting in 7 1 Program pattern setting 1 Time signal ON OFF operation The time signal is OFF during corresponding segment operation when 0 is selected The change is imp...

Page 64: ...e and operation time The time signal is ON after setting time is elapsed in delay time from the corresponding segment starting point However the time signal is not operated when the corresponding segm...

Page 65: ...N time Delay time Operation time ON Time signal OFF Operation time ON Time signal OFF Operation time Delay time 3 Delay time 000 00 00 4 Delay time 000 00 00 1 Delay time 000 00 00 2 Delay time 000 0...

Page 66: ...ation is applied to the set entire segment in 7 1 Program pattern setting Maintain SEG The standby operation is applied only to the set maintain range segment in 7 1 Program pattern setting It is a sc...

Page 67: ...and humidity standby operation range for humidity Standby set time Segment n 1 setting time Segment n 1 setting time Standby operation range Standby operation range Standby operation Time stop Segment...

Page 68: ...Converting to the next or previous experiment name screen Experiment name 1 120 0 9 A Z Special letter Maximum 24 letters ABS EXPERIMENT OF PATTERN 1 120 Fig 7 12 Experiment name setting screen Refere...

Page 69: ...Part 08 Screen display setting 8 1 Setting display setting 69 8 2 DI error creation history view 71...

Page 70: ...68 Part 08 Flow chart Fig 8 1 Screen display setting screen Fig 8 3 DI error creation history screen Setting display setting...

Page 71: ...to select the basic background color 08 Setting display setting 8 1 Screen display setting Fig 8 1 Screen display setting screen It converts to Fig 8 1 Screen display setting screen when the screen d...

Page 72: ...sound The buzzer sound generated in DI error is operated when it is set for no use It sets the backlight electricity saving time The electricity saving time sets the operation timing of backlight OFF...

Page 73: ...saved after deletion of the saved history Fig 8 3 DI error creation history screen It displays the history of DI error creation The name set in 11 2 Error name in Operation manual is displayed The cha...

Page 74: ...ing button after DI creation Here the neglecting means the DI error screen Ex It neglects even DI1 is created by escaping with Return in the stat of DI1 creation and the DI error screen is displayed w...

Page 75: ...Part 09 Communication error 74...

Page 76: ...splayed at the top of the screen as shown in Fig 10 1 Control part communication error screen When there is an error between control part and I O board communication The message The I O board is not c...

Page 77: ...tialized Download the instruction manual and communication manual from the homepage EU Value of engineering unit depending on the range of instrument EUS Value of engineering unit depending on the spa...

Page 78: ...MEMO...

Page 79: ......

Page 80: ......