© SAMSUNG Telecommunications America
6
Wireless Line Interface - WLI
REQUIREMENTS:
1.
A working iDCS 500R2/100R2 or OS7200 VoWLAN system
2.
A PC with serial cable to connect to WLI serial port
a.
S4WLI for 100R2 requires cross over 9-pin serial cable.
b.
8WLI for 500R2 requires straight 9-pin serial cable.
c.
4WLI for 7200 requires 9-pin serial cable to RJ-45 connector
i.
SIO pin 2 (TX) to RJ45 Pin 3 (TX)
ii.
SIO pin 3 (RX) to RJ45 Pin 6 (RX)
iii.
SIO pin 5 (GND) to RJ45 Pin 4 (GND)
3.
Terminal emulation SW ex. “Tera Terminal”
STEPS:
1.
Use “Tera Terminal” with the following serial port setting
a.
Bits per second: 9600
b.
Data bits: 8
c.
Parity: none
d.
Stop bits: 1
e.
Flow control: none
2.
After establish communications, press <enter> key then the screen will show WLI>
3.
Enter “flo”
4.
Select ‘1’ then the following message will show up.
Selected 1> Single- WLI HEX FILE Loading
Please Start Loading!!
5.
Click the ‘Send file’ under File Menu.
6.
Go to the file folder and select the “WLIROM.HEX” file and click the [Ok] button. Example of the
file name convention”
a.
iDCS 500R2: 8WLIROM.HEX
b.
iDCS 100R2: MWLIROM.HEX
c.
OS 7200: 4WLIROM.HEX
7.
The screen will show the file updating status.
a.
During this process, all APs are turned off.