Exit test mode – hold the Cancel/Delete button for 6 seconds to go back to normal display
Operation
Button
Display
Enter test mode – hold
Blue set button
and the Test button together for 5
seconds
Run the water circulation pump (B6 live) – Press the Heating on/off button
Run the Backup heater/boiler (B2 live) – press the Mode button (Heating)
Run the immersion heater (Terminal A3&A4) – press the Weekly button
Run the Hybrid Boiler (B4 live) – press the Set button
Open the Hot Water Zone Valve (B8 live) – press the Lock Button
Open valve for heating Zone 1 (B12 live) – press the DHW on/off button
Open valve for heating Zone 2 (B16 live) – press the Mode button (DHW)
Show 5 temperature sensor values in order – press
the View button
.
Return temperature
Flow temperature (From heat pump)
Flow temperature (From hybrid boiler)
Hot water cylinder temperature
Temperature of the inside of the house
Run signal coming back from heating zone 1 thermostat into terminal B22
Run signal coming back from heating zone 2 thermostat into terminal B24