OfficeServ 7200-S
INSTALLATION
TECHNICAL MANUAL
PART 5 MAY 2010
5.3
The following chart provides current ratings for various devices connected to the system:
Table 5.1 Consumption per Device
Card Name
Connected
Device Type
Current Consumption
per Each Device (mA)
DLI
Digital Keyset
25
MWSLI
Analog Phone
25
Analog Phone with Message Waiting
Lamp
30
GPLIMT/
PLIM/PLIM2
ITP-5121D or ITP-5107S
100
ITP-5112L
130
SMT-R2000 Dual AP
200
Other IEEE 802.3af compliant device.
See manufacture current draw
specifications
Card Name
Connected
Device Type
Current Consumption
per Each Device (mA)
DLI
Digital Keyset
25
MWSLI
Analog Phone
25
Analog Phone with Message Waiting
Lamp
30
GPLIMT/PLIM/
PLIM2
(48 V)
ITP-5121D or ITP-5107S
100
ITP-5112L
130
SMT-R2000 Dual AP
200
SMT-i3105
83
SMT-i5210
127
SMT-i5220, SMT-i5230
107
SMT-i5243
156
SMT-i5264
100
A52GE Gigabit
56
Other IEEE 802.3af compliant device.
See manufacture current draw specifications
IF ADDING GPLIMT/PLIM/PLIM2 CONNECTED DEVICES CAUSE CURRENT DRAWN TO EXCEED
2200mA PER CABINET (not per system), THEN YOU MUST CONNECT THE OS7150 EXTERNAL
PoE POWER SUPPLY MODULE to the cabinet. This unit will provide additional power only to
devices connected to GPLIMT/PLIM/PLIM2s when the OS7200 power supply limits have been
exceeded.
It is important to note that the OS 7150 only provides additional power to the
GPLIMT/PLIM/PLIM2. The OS 7150 is used when the GPLIMT/PLIM/PLIM2 connected devices
cause the total current draw per cabinet to exceed 2200 mA. It does
not
provide power to
DLI, and MWSLI ports.
Home Page