PART 1. PRE-INSTALLATION INFORMATION
1.1 SITE REQUIREMENTS
Select a location that satisfies the following conditions for safety, temperature, humidity, power
and grounding.
1.1.1 Safety Conditions
•
The OfficeServ 7200-S system should not be installed near materials that can cause a fire,
such as explosive gas and inflammables. The OfficeServ 7200-S system should not be near
equipment that generate electromagnetic waves, such as monitors or copying machines.
•
The installation location should be convenient for distributing trunk lines and extension
lines, for connecting power and grounding wires, and for maintenance and repair.
•
The OfficeServ 7200-S system should not be installed in aisles or passageways that are
populated or used for moving equipment.
•
Always maintain cleanliness to prevent dust from damaging the board connectors of the
cabinet.
•
Before installing the OfficeServ 7200-S system, check items such as the electrical wiring
status, grounding status, voltage and frequency.
•
Do not expose equipment to direct sun light, corrosive fumes, and constant vibrations.
•
Do not install in close proximity to a fire sprinkler or other sources of water.
•
A dedicated commercial AC power outlet is required. Do not use extension cords.
•
Ensure that all wires and cables to and from the OfficeServ 7200-S do not cross fluorescent
lights or run in parallel with AC wires.
•
This equipment is to be installed only in restricted access areas (dedicated, equipment
closets, etc.) in accordance with articles 110-16, 110-17, 110-18 of the National Electric
Code, ANSI/NFPA 70.
1.1.2
Temperature/Humidity Conditions
The conditions for temperature and humidity are as follows:
•
Operation temperature: 32°F~113°F
•
Storage temperature: 14°F~122°F
•
Humidity: 10~90%