3.2 DIMENSIONS
The OfficeServ 7200-S consists of one cabinet shown in the figure below:
Note: When the cabinet is rack mounted, the rack mount bracket will add some heighth to the system.
*This the maximum distance a door phone can be from the DPIM. The DPIM can be up to 900 cable feet from the
KSU. The total distance must not exceed 1230 feet.
3.2
FIGURE 3-2
System Cabinet
HEIGHT
WIDTH
DEPTH
OfficeServ 7200-S Cabinet
4.87”
17.32”
16.14”
3.3 ENVIRONMENTAL LIMITS
OPERATING TEMPERATURE
32—113 °F / 0—45 °C
STORAGE TEMPERATURE
14—122 °F / --10—50 °C
HUMIDITY
10%—90% Non-Condensing
3.4 CABLE REQUIREMENTS
EQUIPMENT
CABLE
AWG
MAX FEET
MAX METERS
DIGITAL KEYSET
1 PR. TWISTED
24
1300
400
ADD-ON MODULE
1 PR. TWISTED
24
1300
400
SINGLE LINE STATION
1 PR. TWISTED
24
3000
1 KM
DOOR PHONE
2 PR. TWISTED
24
330*
100
BTU
MAXIMUM LOAD
70% LOAD
Wattage
BTU/h
BTU/min
Wattage
BTU/h
BTU/min
210.3W
717.8
11.96
147.21W
502.4
8.37
Home Page