3.6 IP Port Table
3.6.1 OfficeServ 7000 Families IP Port Numbers
The IP Port Numbers used in OfficeServ 7000 families are shown in the table below:
Table 3.13 OfficeServ 7000 Families IP Port Numbers
Category
Service Type
Protocol
Port Number
Remarks
6100
For connection setup
SPnet
TCP
1024~4999
For maintaining TCP
Connection
TCP, UDP
6000
For connection setup
IP Phone
interface
UDP
1024~4999
For signaling to IP phone
UDP
1719
For connection with
Gatekeeper
1720
For connection setup
H.323 Gateway
TCP
1024~4999
For maintaining TCP
Connection
SIP Gateway
UDP
5060
For connection setup
OSM interface
TCP
5000, 5200
OSM connection
CTI interface
5002
CTI Connection
Program Upload
5003
Program upload to Media
card
OfficeServ News
5012
OfficeServ News Server
connection
WebMMC
5080, 5081
OfficeServ 7400 WebMMC
connection
Installation Tool
5090, 5091
OfficeServ Installation Tool
connection
7030 Web
(internal)
5092, 5093
Web Server-MP/ VM/Router
connection
reserved
5000~5099
Reserved for new service
SMDR Report
5100
SMDR printout to IP
connection
UCD Report
5101
UCD printout to IP connection
Traffic Report
5102
Traffic Report to IP
connection
System
Alarm Report
TCP
5103
System Alarm Report to IP
connection