Appendix A-3
Parameter Check List
Name
Unit
Display
Page
U3.01
Modified Parameter List
-
“----” (None)
5-5
U3.02
Fault Parameter List
-
“----” (None)
5-5
B-parameter
Basic Setup
Name
Unit
Setting
Range
Factory
Setting
Changeable
During Operation
Page
B0.01
Active Source of
Frequency Command
- 00~23 00
X
5-10
B0.02
Active Source of
RUN Command
- 00~12 00
X
5-10
B0.03 Stopping Method
-
0~1
0
X
5-11
B0.04
Prohibiting
Reverse Rotation
- 0~1 0
X
5-11
B0.05
Default Motor
Direction
- 0~1 0
O
5-12
B0.06 Default Monitor Item
-
1~10
0
O
5-12
B0.07
Automatic Start after
Power On
- 0~1 0
O
5-12
System Initialization
Name
Unit
Setting
Range
Factory
Setting
Changeable
During Operation
Page
B1.01
Inverter
Initialization
- 0~9999 0000
X
5-13
B1.02 Check
Password
-
0~9999 0000
X
5-14
B1.03 Set
Password
- 0~9999 0000
X
5-14
System Capacity Setup
Name
Unit
Setting
Range
Factory
Setting
Changeable
During Operation
Page
B2.01
Power Capacity of
the Inverter
- 20P4~43P7 -
X
5-14
B2.02
Power Capacity of
the Motor
- 20P4~43P7 -
X
5-14
A-4
MOSCON-E7 User’s Manual
F-parameter
Frequency/Speed Command
Name
Unit
Setting
Range
Factory
Setting
Changeable
During operation
Page
F0.01
Main Frequency
Command of
Operator Mode &
Communication
Mode
0.01Hz 0.00~600.00
0.00
○
5-15
F0.02 Frequency2 0.01Hz 0.00~600.00
0.00
○
5-15
F0.03 Frequency3 0.01Hz 0.00~600.00
0.00
○
5-15
F0.04 Frequency4 0.01Hz 0.00~600.00
0.00
○
5-15
F0.05 Frequency5 0.01Hz 0.00~600.00
0.00
○
5-15
F0.06 Frequency6 0.01Hz 0.00~600.00
0.00
○
5-15
F0.07 Frequency7 0.01Hz 0.00~600.00
0.00
○
5-15
F0.08 Frequency8 0.01Hz 0.00~600.00
0.00
○
5-15
F0.09 Jog
Frequency 0.01Hz 0.00~600.00
6.00
○
5-15
Frequency Limit
Name
Unit
Setting
Range
Factory
Setting
Changeable
During Operation
Page
F1.01 High
Speed
Limit 0.1%
0.1~100.0
100.0
○
5-16
F1.02 Low Speed Limit
0.1%
0.0~99.9
0.0
○
5-16
Jump Frequency Limit
Name
Unit
Setting
Range
Factory
Setting
Changeable
During Operation
Page
F1.03 Jump
Frequency1 0.01Hz 0.00~600.00
0.00
○
5-16
F1.04 Jump
Frequency2 0.01Hz 0.00~600.00
0.00
○
5-16
F1.05 Jump
Frequency3 0.01Hz 0.00~600.00
0.00
○
5-16
F1.06
Jump Frequency
Width
0.01Hz 0.00~20.00
0.50
○
5-16
F1.07 Jump
Mode
-
0~1
0
X
5-17
Frequency Detection
Name
Unit
Setting
Range
Factory
Setting
Changeable
During Operation
Page
F1.08
Frequency of
Match Detection
0.01Hz 0.00~600.00
0.00
○
5-19
F1.09
Frequency Match
Detection Width
0.01Hz 0.00~20.00
0.50
○
5-19
F1.10
Frequency of
Accel/Decel
Time Switching
0.01Hz 0.00~600.00
0.00
○
5-19