Appendix A-5
Accel/Decel Time
Name
Unit
Setting
Range
Factory
Setting
Changeable
During Operation
Page
F2.01
Accel Time 1
0.01sec 0.00~600.00
10.00
○
5-20
F2.02 Decel
Time
1 0.01sec
0.00~600.00 10.00
○
5-20
F2.03
Accel Time 2
0.01sec 0.00~600.00
10.00
○
5-20
F2.04 Decel
Time
2 0.01sec
0.00~600.00 10.00
○
5-20
F2.05
Accel/Decel
Time Base
- 0~1 0
X
5-20
S-Curve Accel/Decel Time
Name
Unit
Setting
Range
Factory
Setting
Changeable
During Operation
Page
F3.01 S-Curve
Time 0.01sec 0.00~2.50 0.20
○
5-21
S-parameter
DC Braking
Name
Unit
Setting
Range
Factory
Setting
Changeable
During Operation
Page
S0.01
DC Brake
Starting Frequency
0.01Hz 0.00~10.00 1.50
X
5-22
S0.02
DC Brake
Current
1% 0~100 50
X
5-22
S0.03
DC Braking Time
at Start
0.1sec 0.0~25.0 0.0
X
5-22
S0.04
DC Braking Time
at Stop
0.1sec 0.0~25.0 0.5
X
5-22
Speed Search
Name
Unit
Setting
Range
Factory
Setting
Changeable
During Operation
Page
S1.01
Speed Search
at Start
- 0~1 0
X
5-23
S1.02
Speed Search
Start Frequency
0.01Hz
0.00~600.00 0.00
X
5-23
S1.03
Speed Search
Current
1%
0~200
100
X
5-23
S1.04
Speed Search
Deceleration Time
0. 1sec
0~10.0
2.0
X
5-23
A-6
MOSCON-E7 User’s Manual
Dwell Operation
Name
Unit
Setting
Range
Factory
Setting
Changeable
During Operation
Page
S2.01
Dwell Frequency
at Start
0.01Hz 0.00~600.0 0.00
X
5-25
S2.02
Dwell Time
at Start
0.01sec 0.00~25.00 0.00
X
5-25
S2.03
Dwell Frequency
at Stop
0.01Hz 0.00~600.0 0.00
X
5-25
S2.04
Dwell Time
at Stop
0.01sec 0.00~25.00 0.00
X
5-25
Energy Save Function
Name
Unit
Setting
Range
Factory
Setting
Changeable
During Operation
Page
S3.01
Energy Saving
Voltage Level
1% 0~100 80
X
5-26
S3.02
Energy Saving
Frequency Level
0.01Hz 0.00~600.00
0.00
X
5-26
Slip Compensation
Name
Unit
Setting
Range
Factory
Setting
Changeable
During Operation
Page
S4.01
Slip Compensation
Gain
1% 0~S4.03 0
○
5-27
S4.02
Slip Compensation
Delay Time
1msec 0~9999 200
X
5-27
S4.03
Slip Compensation
Limit
1% 0~250 200
X
5-27
Torque Compensation
Name
Unit
Setting
Range
Factory
Setting
Changeable
During Operation
Page
S5.01
Torque
Compensation
Gain
1% 0~250 100
X
5-29
S5.02
Torque
Compensation
Delay time
1msec 0~9999 20
X
5-29
System function Compensation
Name
Unit
Setting
Range
Factory
Setting
Changeable
During Operation
Page
S6.01
Hunting
Prevention Gain
% 0~100 20
○
5-30
S6.02
Enable
Brake Boosting
- 0~1 0
X
5-30
S6.03
Current ripple
restraint
(1 phase only)
- 0~1 1
X
5-30