S3C8248/C8245/P8245/C8247/C8249/P8249
16-BIT TIMER 0/1
12-7
TIMER 1 CONTROL REGISTER (T1CON)
You use the timer 1 control register, T1CON, to
— Select the timer 1 operating mode (interval timer, capture mode, or PWM mode)
— Select the timer 1 input clock frequency
— Clear the timer 1 counter, T1CNTH/L
— Enable the timer 1 overflow interrupt or timer 1 match/capture interrupt
— Clear timer 1 match/capture interrupt pending conditions
T1CON is located in set 1 and Bank 1 at address FBH, and is read/write addressable using Register addressing
mode.
A reset clears T1CON to ‘00H’. This sets timer 1 to normal interval timer mode, selects an input clock frequency
of fxx/1024, and disables all timer 1 interrupts. To disable the counter operation, please set T1CON.7-.5 to 111B.
You can clear the timer 1 counter at any time during normal operation by writing a “1” to T1CON.3.
The timer 1 overflow interrupt (T1OVF) is interrupt level IRQ3 and has the vector address EAH. When a timer 1
overflow interrupt occurs and is serviced interrupt (IRQ3, vector E8H), you must write T1CON.1 to “1”. To
generate the exact time interval, you should write T1CON by the CPU, the pending condition is cleared
automatically by hardware.
To enable the timer 1 match/capture which clear counter and interrupt pending bit. To detect a match/capture or
overflow interrupt pending condition when T1INT or T1OVF is disabled, the application program should poll the
pending bit. When a “1” is detected, a timer 1 match/capture or overflow interrupt is pending.
When her sub-routine has been serviced, the pending condition must be cleared by software by writing a “0” to
the interrupt pending bit.
Timer 1 Control Register (T1CON)
FBH, Set 1, Bank 1, R/W
.7
.6
.5
.4
.3
.2
.1
.0
MSB
LSB
Timer 1 match/capture interrupt enable bit:
0 = Disable interrupt
1 = Enable interrupt
Timer 1 overflow interrupt enable:
1 = Enable overflow interrupt
0 = Disable overflow interrupt
Timer 1 counter clear bit:
0 = No effect
1 = Clear the timer 1 counter
(when write)
Timer 1 input clock selection bits:
000 = f
XX
/1024
010 = f
XX
/256
100 = f
XX
/64
110 = f
XX
/8
001 = f
XX
/1
011 = External clock (T1CLK) falling edge
101 = External clock (T1CLK) rising edge
111 = Counter stop
Timer 1 operating mode selection bits:
00 = Interval mode
01 = Capture mode (capture on rising edge, counter running, OVF can occur)
10 = Capture mode (capture on falling edge, counter running, OVF can occur)
11 = PWM mode
(OVF & match interrupt can occur)
Figure 12-5. Timer 1 Control Register (T1CON)
Summary of Contents for C8245
Page 31: ...ADDRESS SPACES S3C8248 C8245 P8245 C8247 C8249 P8249 2 20 NOTES ...
Page 107: ...INTERRUPT STRUCTURE S3C8248 C8245 P8245 C8247 C8249 P8249 5 18 NOTES ...
Page 195: ...INSTRUCTION SET S3C8248 C8245 P8245 C8247 C8249 P8249 6 88 NOTES ...
Page 221: ...I O PORTS S3C8248 C8245 P8245 C8247 C8249 P8249 9 16 NOTES ...
Page 245: ...16 BIT TIMER 0 1 S3C8248 C8245 P8245 C8247 C8249 P8249 12 10 NOTES ...
Page 249: ...WATCH TIMER S3C8248 C8245 P8245 C8247 C8249 P8249 13 4 NOTES ...
Page 267: ...A D CONVERTER S3C8248 C8245 P8245 C8247 C8249 P8249 15 6 NOTES ...
Page 299: ...S3P8245 P8249 OTP S3C8248 C8245 P8245 C8247 C8249 P8249 21 8 NOTES ...
Page 307: ......
Page 309: ......
Page 311: ......
Page 313: ......